Show plain JSON{"id": "CVE-2019-13934", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 3.5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "authentication": "SINGLE", "integrityImpact": "PARTIAL", "accessComplexity": "MEDIUM", "availabilityImpact": "NONE", "confidentialityImpact": "NONE"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "LOW", "obtainAllPrivilege": false, "exploitabilityScore": 6.8, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true}], "cvssMetricV31": [{"type": "Secondary", "source": "productcert@siemens.com", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 3.5, "attackVector": "NETWORK", "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N", "integrityImpact": "NONE", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "LOW", "confidentialityImpact": "LOW"}, "impactScore": 1.4, "exploitabilityScore": 2.1}, {"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "CHANGED", "version": "3.1", "baseScore": 5.4, "attackVector": "NETWORK", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "integrityImpact": "LOW", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "LOW", "confidentialityImpact": "LOW"}, "impactScore": 2.7, "exploitabilityScore": 2.3}]}, "published": "2019-11-27T14:15:10.970", "references": [{"url": "https://xavibel.com/2019/11/25/siemens-polarion-multiple-web-vulnerabilities/", "tags": ["Vendor Advisory"], "source": "productcert@siemens.com"}, {"url": "https://xavibel.com/2019/11/25/siemens-polarion-multiple-web-vulnerabilities/", "tags": ["Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "productcert@siemens.com", "description": [{"lang": "en", "value": "CWE-79"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-79"}]}], "descriptions": [{"lang": "en", "value": "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2."}, {"lang": "es", "value": "Una vulnerabilidad de Neutralizaci\u00f3n Inapropiada de Entrada Durante la Generaci\u00f3n de P\u00e1ginas Web (\"Cross-site Scripting\") en el cliente web de Siemens AG Polarion podr\u00eda permitir a un atacante explotar una vulnerabilidad de tipo XSS reflejado. Este problema afecta a: Siemens AG Polarion Todas las versiones anteriores a la versi\u00f3n 19.2."}], "lastModified": "2024-11-21T04:25:43.740", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:siemens:polarion:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "BAD4D203-D43F-4C53-A415-4126E2F3DDE7", "versionEndExcluding": "19.2"}], "operator": "OR"}]}], "sourceIdentifier": "productcert@siemens.com"}