Show plain JSON{"id": "CVE-2018-7798", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 6.4, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "NONE"}, "acInsufInfo": false, "impactScore": 4.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 8.2, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "LOW", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 4.2, "exploitabilityScore": 3.9}]}, "published": "2018-11-02T17:29:00.680", "references": [{"url": "http://www.securityfocus.com/bid/105970", "tags": ["Third Party Advisory", "VDB Entry"], "source": "cybersecurity@se.com"}, {"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-270-01/", "tags": ["Mitigation", "Vendor Advisory"], "source": "cybersecurity@se.com"}, {"url": "http://www.securityfocus.com/bid/105970", "tags": ["Third Party Advisory", "VDB Entry"], "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-270-01/", "tags": ["Mitigation", "Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-345"}]}], "descriptions": [{"lang": "en", "value": "A Insufficient Verification of Data Authenticity (CWE-345) vulnerability exists in the Modicon M221, all versions, which could cause a change of IPv4 configuration (IP address, mask and gateway) when remotely connected to the device."}, {"lang": "es", "value": "Existe una vulnerabilidad de verificaci\u00f3n insuficiente de autenticidad de datos (CWE-345) en Modicon Modicon M221, todas las versiones, lo que podr\u00eda provocar un cambio en la configuraci\u00f3n IPv4 (direcci\u00f3n IP, m\u00e1scara y puerta de enlace) al conectarse remotamente al dispositivo."}], "lastModified": "2024-11-21T04:12:45.347", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:somachine_basic:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "2BCEA269-6242-41FD-B141-F72CAFC8F114"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:schneider-electric:modicon_m221:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "BB0D83F4-B718-47AB-AFB8-B576CB138AAC"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "cybersecurity@se.com"}