| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence (All versions < V2501.0001), Opcenter Quality (All versions < V2512), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component.
This could allow an unauthenticated remote attacker to execute arbitrary code. |
| Cattown is a JavaScript markdown parser. Versions prior to 1.0.2 used regular expressions with inefficient, potentially exponential worst-case complexity. This could cause excessive CPU usage due to excessive backtracking on crafted inputs. In turn, the excessive CPU usage could lead to resource exhaustion, where processing malicious inputs could cause high CPU or memory usage, potentially leading to denial of service. Version 1.0.2 contains a patch. Additionally, users should review and restrict input sources if untrusted inputs are processed. |
| A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code. |
| Asseco InfoMedica is a comprehensive solution used to manage both administrative and medical tasks in the healthcare sector. A low privileged user is able to obtain encoded passwords of all other accounts (including main administrator) due to lack of granularity in access control.
Chained exploitation of this vulnerability and CVE-2025-8307 allows an attacker to escalate privileges. This vulnerability has been fixed in versions 4.50.1 and 5.38.0 |
| Improper restriction of operations within the bounds of a memory buffer in PCIe® Link could allow an attacker with access to a guest virtual machine to potentially perform a denial of service attack against the host resulting in loss of availability. |
| Promptcraft Forge Studio is a toolkit for evaluating, optimizing, and maintaining LLM-powered applications. All versions contain an non-exhaustive URL scheme check that does not protect against XSS. User-controlled URLs pass through src/utils/validation.ts, but the check only strips `javascript:` and a few patterns. `data:` URLs (for example data:image/svg+xml,…) still pass. If a sanitized value is used in href/src, an attacker can execute a script. There is currently no fix for this issue. |
| Promptcraft Forge Studio is a toolkit for evaluating, optimizing, and maintaining LLM-powered applications. All versions of Promptcraft Forge Studio sanitize user input using regex blacklists such as r`eplace(/javascript:/gi, '')`. Because the package uses multi-character tokens and each replacement is applied only once, removing one occurrence can create a new dangerous token due to overlap. The “sanitized” value may still contain an executable payload when used in href/src (or injected into the DOM). There is currently no fix for this issue. |
| A vulnerability was identified in INSTAR 2K+ and 4K 3.11.1 Build 1124. This affects the function base64_decode of the component fcgi_server. The manipulation of the argument Authorization leads to buffer overflow. It is possible to initiate the attack remotely. |
| Out-of-bounds Read in lws_upng_emit_next_line in warmcat libwebsockets allows, when the LWS_WITH_UPNG flag is enabled during compilation and the HTML display stack is used, to read past a heap allocated buffer possibly causing a crash, when the user visits an attacker controlled website that contains a crafted PNG file with a big height dimension. |
| A vulnerability was found in xujeff tianti 天梯 up to 2.3. It has been rated as problematic. This issue affects the function exportOrder of the file /tianti-module-admin/user/ajax/save of the component com.jeff.tianti.controller. The manipulation leads to csv injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A weakness has been identified in UGREEN DH2100+ up to 5.3.0.251125. This affects the function handler_file_backup_create of the file /v1/file/backup/create of the component nas_svr. Executing a manipulation of the argument path can lead to buffer overflow. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks. It is recommended to upgrade the affected component. |
| libsmb2 6.2+ is vulnerable to Buffer Overflow. When processing SMB2 chained PDUs (NextCommand), libsmb2 repeatedly calls smb2_add_iovector() to append to a fixed-size iovec array without checking the upper bound of v->niov (SMB2_MAX_VECTORS=256). An attacker can craft responses with many chained PDUs to overflow v->niov and perform heap out-of-bounds writes, causing memory corruption, crashes, and potentially arbitrary code execution. The SMB2_OPLOCK_BREAK path bypasses message ID validation. |
| Improper bound check within AMD CPU microcode can allow a malicious guest to write to host memory, potentially resulting in loss of integrity. |
| Affected is an unknown function of the component Login Page. The manipulation leads to improper restriction of rendered ui layers. It is possible to launch the attack remotely. |
| Fuji Electric Smart Editor is vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code. |
| Improper restriction of rendered UI layers or frames issue exists in HMI ViewJet C-more series, which may allow a remote unauthenticated attacker to trick the product user to perform operations on the product's web pages. |
| RabidHamster R4 v1.25 contains a stack-based buffer overflow vulnerability due to unsafe use of sprintf() when logging malformed HTTP requests. A remote attacker can exploit this flaw by sending a specially crafted URI, resulting in arbitrary code execution under the context of the web server process. |
| Software installed and run as a non-privileged user may conduct improper GPU system calls to cause kernel system memory corruption. |
| mmstu.c in VideoLAN VLC media player before 3.0.22 allows an out-of-bounds read and denial of service via a crafted 0x01 response from an MMS server. |
| A vulnerability classified as critical has been found in Sony SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N and SNC-RX570N up to 1.30. This affects an unknown part of the component Administrative Interface. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. It is recommended to change the configuration settings. The vendor was contacted early about this issue. They confirmed the existence but pointed out that they "have published the 'Hardening Guide' on the Web from July 2018 to January 2025 and have thoroughly informed customers of the recommendation to change their initial passwords". |