Export limit exceeded: 412929 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (2533 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-10334 2026-04-15 7.3 High
A vulnerability exists in the VideONet product included in the listed System 800xA versions, where VideONet is used.  An attacker who successfully exploited the vulnerability could, in the worst case scenario, stop or manipulate the video feed. This issue affects System 800xA: 5.1.X; System 800xA: 6.0.3.X; System 800xA: 6.1.1.X; System 800xA: 6.2.X.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2025-8904 1 Amazon 1 Emr 2026-04-15 8.5 High
Amazon EMR Secret Agent creates a keytab file containing Kerberos credentials. This file is stored in the /tmp/ directory. A user with access to this directory and another account can potentially decrypt the keys and escalate to higher privileges. Users are advised to upgrade to Amazon EMR version 7.5 or higher. For Amazon EMR releases between 6.10 and 7.4, we strongly recommend that you run the bootstrap script and RPM files with the fix provided in the location below.
CVE-2025-23395 2026-04-15 7.8 High
Screen 5.0.0 when it runs with setuid-root privileges does not drop privileges while operating on a user supplied path. This allows unprivileged users to create files in arbitrary locations with `root` ownership, the invoking user's (real) group ownership and file mode 0644. All data written to the Screen PTY will be logged into this file, allowing to escalate to root privileges
CVE-2025-1394 1 Silabs 1 Emberznet 2026-04-15 N/A
The Ember ZNet stack’s packet buffer manager may read out of bound memory leading to an assert, causing a Denial of Service (DoS).
CVE-2025-8907 2026-04-15 7 High
A vulnerability was found in H3C M2 NAS V100R006. Affected by this vulnerability is an unknown functionality of the component Webserver Configuration. The manipulation leads to execution with unnecessary privileges. An attack has to be approached locally. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor explains: "[T]he device only has configuration files and does not actually have boa functionality. It is impossible to access or upload files anonymously to the device through boa services". This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2025-9055 3 Axis, Axis Communications Ab, Linux 3 Axis Os, Axis Os, Linux 2026-04-15 6.4 Medium
The VAPIX Edge storage API that allowed a privilege escalation, enabling a VAPIX administrator-privileged user to gain Linux Root privileges. This flaw can only be exploited after authenticating with an administrator-privileged service account.
CVE-2025-9380 1 Fnkvision 1 Y215 Cctv Camera 2026-04-15 7.8 High
A vulnerability was identified in FNKvision Y215 CCTV Camera 10.194.120.40. Affected by this issue is some unknown functionality of the file /etc/passwd of the component Firmware. Such manipulation leads to hard-coded credentials. Local access is required to approach this attack. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-50590 1 Hasomed 1 Elefant 2026-04-15 7.8 High
Attackers with local access to the medical office computer can escalate their Windows user privileges to "NT AUTHORITY\SYSTEM" by overwriting one of two Elefant service binaries with weak permissions. The default installation directory of Elefant is "C:\Elefant1" which is writable for all users. In addition, the Elefant installer registers two Firebird database services which are running as “NT AUTHORITY\SYSTEM”.  Path: C:\Elefant1\Firebird_2\bin\fbserver.exe Path: C:\Elefant1\Firebird_2\bin\fbguard.exe Both service binaries are user writable. This means that a local attacker can rename one of the service binaries, replace the service executable with a new executable, and then restart the system. Once the system has rebooted, the new service binary is executed as "NT AUTHORITY\SYSTEM".
CVE-2025-13221 1 Intelbras 1 Unniti 2026-04-15 5.3 Medium
A weakness has been identified in Intelbras UnniTI 24.07.11. The affected element is an unknown function of the file /xml/sistema/usuarios.xml. Executing manipulation of the argument Usuario/Senha can lead to unprotected storage of credentials. The attack can be executed remotely. The exploit has been made available to the public and could be exploited.
CVE-2025-6949 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A critical authorization flaw in the API allows an authenticated, low-privileged user to create a new administrator account, including accounts with usernames identical to existing users. In certain scenarios, this vulnerability could allow an attacker to gain full administrative control over the affected device, leading to potential account impersonation. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems.
CVE-2024-51722 1 Blackberry 1 Secusuite 2026-04-15 6.4 Medium
A local privilege escalation vulnerability in the SecuSUITE Server (System Configuration) of SecuSUITE versions 5.0.420 and earlier could allow a successful attacker that had gained control of code running under one of the system accounts listed in the configuration file to potentially issue privileged script commands.
CVE-2025-6894 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in the API authorization logic of the affected device allows an authenticated, low-privileged user to execute the administrative `ping` function, which is restricted to higher-privileged roles. This vulnerability enables the user to perform internal network reconnaissance, potentially discovering internal hosts or services that would otherwise be inaccessible. Repeated exploitation could lead to minor resource consumption. While the overall impact is limited, it may result in some loss of confidentiality and availability on the affected device. There is no impact on the integrity of the device, and the vulnerability does not affect any subsequent systems.
CVE-2025-6893 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in broken access control has been identified in the /api/v1/setting/data endpoint of the affected device. This flaw allows a low-privileged authenticated user to call the API without the required permissions, thereby gaining the ability to access or modify system configuration data. Successful exploitation may lead to privilege escalation, allowing the attacker to access or modify sensitive system settings. While the overall impact is high, there is no loss of confidentiality or integrity within any subsequent systems.
CVE-2024-5275 1 Fortra 2 Filecatalyst Direct, Filecatalyst Workflow 2026-04-15 7.8 High
A hard-coded password in the FileCatalyst TransferAgent can be found which can be used to unlock the keystore from which contents may be read out, for example, the private key for certificates. Exploit of this vulnerability could lead to a machine-in-the-middle (MiTM) attack against users of the agent. This issue affects all versions of FileCatalyst Direct from 3.8.10 Build 138 and earlier and all versions of FileCatalyst Workflow from 5.1.6 Build 130 and earlier.
CVE-2025-54754 1 Cognex 2 In-sight Camera Firmware, In-sight Explorer 2026-04-15 8 High
An attacker with adjacent access, without authentication, can exploit this vulnerability to retrieve a hard-coded password embedded in publicly available software. This password can then be used to decrypt sensitive network traffic, affecting the Cognex device.
CVE-2024-52799 1 Argoproj 1 Argo-helm 2026-04-15 8.3 High
Argo Workflows Chart is used to set up argo and its needed dependencies through one command. Prior to 0.44.0, the workflow-role has excessive privileges, the worst being create pods/exec, which will allow kubectl exec into any Pod in the same namespace, i.e. arbitrary code execution within those Pods. If a user can be made to run a malicious template, their whole namespace can be compromised. This affects versions of the argo-workflows Chart that use appVersion: 3.4 and above, which no longer need these permissions for the only available Executor, Emissary. It could also affect users below 3.4 depending on their choice of Executor in those versions. This only affects the Helm Chart and not the upstream manifests. This vulnerability is fixed in 0.44.0.
CVE-2025-61680 2 Jaketcooper, Minecraft 2 Minecraft-rcon, Minecraft 2026-04-15 N/A
Minecraft RCON Terminal is a VS Code extension that streamlines Minecraft server management. Versions 0.1.0 through 2.0.6 stores passwords using VS Code's configuration API which writes to settings.json in plaintext. This issue is fixed in version 2.1.0.
CVE-2025-5379 2026-04-15 4.3 Medium
A vulnerability classified as critical was found in NuCom NC-WR744G 8.5.5 Build 20200530.307. This vulnerability affects unknown code of the component Console Application. The manipulation of the argument CMCCAdmin/useradmin/CUAdmin leads to hard-coded credentials. The attack can be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-61330 1 H3c 1 Magic 2026-04-15 6.5 Medium
A hard-coded weak password vulnerability has been discovered in all Magic-branded devices from Chinese network equipment manufacturer H3C. The vulnerability stems from the use of a hard-coded weak password for the root account in the /etc/shadow configuration or even the absence of any password at all. Some of these devices have the Telnet service enabled by default, or users can choose to enable the Telnet service in other device management interfaces (e.g. /debug.asp or /debug_telnet.asp). In addition, these devices have related interfaces called Virtual Servers, which can map the devices to the public network, posing the risk of remote attacks. Therefore, attackers can obtain the highest root privileges of the devices through the Telnet service using the weak password hardcoded in the firmware (or without a password), and remote attacks are possible.