| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Obsidian GitHub Copilot Plugin versions prior to 1.1.7 store Github API token in cleartext form. As a result, an attacker may perform unauthorized operations on the linked Github account. |
| Local Deep Research is an AI-powered research assistant for deep, iterative research. Versions 0.2.0 through 0.6.7 stored confidential information, including API keys, in a local SQLite database without encryption. This behavior was not clearly documented outside of the database architecture page. Users were not given the ability to configure the database location, allowing anyone with access to the container or host filesystem to retrieve sensitive data in plaintext by accessing the .db file. This is fixed in version 1.0.0. |
| This vulnerability exists in ZKTeco WL20 due to storage of Wi-Fi credentials, configuration data and system data in plaintext within the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the plaintext sensitive data stored in the targeted device.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized network access, retrieve and manipulate data on the targeted device. |
| phpgt/Dom provides access to modern DOM APIs. Versions of phpgt/Dom prior to 4.1.8 expose the GITHUB_TOKEN in the Dom workflow run artifact. The ci.yml workflow file uses actions/upload-artifact@v4 to upload the build artifact. This artifact is a zip of the current directory, which includes the automatically generated .git/config file containing the run's GITHUB_TOKEN. Seeing as the artifact can be downloaded prior to the end of the workflow, there is a few seconds where an attacker can extract the token from the artifact and use it with the GitHub API to push malicious code or rewrite release commits in your repository. Any downstream user of the repository may be affected, but the token should only be valid for the duration of the workflow run, limiting the time during which exploitation could occur. Version 4.1.8 fixes the issue. |
| Cleartext Storage of Sensitive Information (CWE-312) in the Gallagher Morpho integration could allow an authenticated user with access to the Command Centre Server to export a specific signing key while in use allowing them to deploy a compromised or counterfeit device on that site.
This issue affects Command Centre Server: 9.20 prior to vEL9.20.2819 (MR4), 9.10 prior to vEL9.10.3672 (MR7), 9.00 prior to vEL9.00.3831 (MR8), all versions of 8.90 and prior. |
| Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files.
This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 |
| An adjacent attacker without authentication can exploit this vulnerability to retrieve a set of user-privileged credentials. These credentials are present during the firmware upgrade procedure. |
| Exposure of Sensitive Information to an Unauthorized Actor, Missing Encryption of Sensitive Data, Files or Directories Accessible to External Parties vulnerability in Kings Information & Network Co. KESS Enterprise on Windows allows Privilege Escalation, Modify Existing Service, Modify Shared File.This issue affects KESS Enterprise: before *.25.9.19.exe |
| A security issue was discovered within the legacy Ansible playbook component of Verve Asset Manager, caused by plaintext secrets incorrectly stored when a playbook is running. This component has been retired and has been optional since the 1.36 release in 2024. |
| A vulnerability was detected in LionCoders SalePro POS up to 5.5.0. This issue affects some unknown processing of the component Login. Performing manipulation results in cleartext transmission of sensitive information. The attack can be initiated remotely. The attack is considered to have high complexity. The exploitability is assessed as difficult. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability has been found in youth-is-as-pale-as-poetry e-learning 1.0. Impacted is the function encryptSecret of the file e-learning-master\exam-api\src\main\java\com\yf\exam\ability\shiro\jwt\JwtUtils.java of the component JWT Token Handler. The manipulation leads to insufficiently random values. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitability is considered difficult. The exploit has been disclosed to the public and may be used. |
| All WorkExaminer Professional traffic between monitoring client, console and server is transmitted as plain text. This allows an attacker with access to the network to read the transmitted sensitive data. An attacker can also freely modify the data on the wire. The monitoring clients transmit their data to the server using the unencrypted FTP. Clients connect to the FTP server on port 12304 and transmit the data unencrypted. In addition, all traffic between the console client and the server at port 12306 is unencrypted. |
| CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists that could result in the exposure
of data when network traffic is being sniffed by an attacker. |
| A Credential Exposure Vulnerability exists in the above-mentioned product and version. The vulnerability is due to using HTTP resulting in credentials being sent in clear text. |
| A vulnerability in the IPS Manager, Central Manager, and Local Manager communication workflow allows an attacker to control the destination of a request by manipulating the parameter, thereby leveraging sensitive information. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device. |
| Hathway Skyworth Router CM5100-511 v4.1.1.24 was discovered to store sensitive information about USB and Wifi connected devices in plaintext. |
| Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.
The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.
This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49. |
| Unauthorized disclosure of sensitive data: Any user with `GET` or `LIST` permissions on `BundleDeployment` resources could retrieve Helm values containing credentials or other secrets. |
| Pterodactyl is a free, open-source game server management panel. When a user disables two-factor authentication via the Panel, a `DELETE` request with their current password in a query parameter will be sent. While query parameters are encrypted when using TLS, many webservers (including ones officially documented for use with Pterodactyl) will log query parameters in plain-text, storing a user's password in plain text. Prior to version 1.11.8, if a malicious user obtains access to these logs they could potentially authenticate against a user's account; assuming they are able to discover the account's email address or username separately. This problem has been patched in version 1.11.8. There are no workarounds at this time. There is not a direct vulnerability within the software as it relates to logs generated by intermediate components such as web servers or Layer 7 proxies. Updating to `v1.11.8` or adding the linked patch manually are the only ways to avoid this problem. As this vulnerability relates to historical logging of sensitive data, users who have ever disabled 2FA on a Panel (self-hosted or operated by a company) should change their passwords and consider enabling 2FA if it was left disabled. While it's unlikely that their account swill be compromised by this vulnerability, it's not impossible. Panel administrators should consider clearing any access logs that may contain sensitive data. |