Search Results (24288 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-48499 1 Fujifilm 8 Apeos 2150, Apeos 2350, Docuprint M115 W and 5 more 2026-04-15 5.3 Medium
Out-of-bounds write vulnerability exists in FUJIFILM Business Innovation MFPs. A specially crafted IPP (Internet Printing Protocol) or LPD (Line Printer Daemon) packet may cause a denial-of-service (DoS) condition on an affected MFP. Resetting the MFP is required to recover from the denial-of-service (DoS) condition.
CVE-2025-48047 2026-04-15 N/A
An authenticated user can perform command injection via unsanitized input to the NetFax Server’s ping functionality via the /test.php endpoint.
CVE-2019-25289 1 Inim 1 Smartliving Smartlan 2026-04-15 8.8 High
SmartLiving SmartLAN <=6.x contains an authenticated remote command injection vulnerability in the web.cgi binary through the 'par' POST parameter with the 'testemail' module. Attackers can exploit the unsanitized parameter and system() function call to execute arbitrary system commands with root privileges using default credentials.
CVE-2017-20216 1 Flir 1 Thermal Camera 2026-04-15 9.8 Critical
FLIR Thermal Camera PT-Series firmware version 8.0.0.64 contains multiple unauthenticated remote command injection vulnerabilities in the controllerFlirSystem.php script. Attackers can execute arbitrary system commands as root by exploiting unsanitized POST parameters in the execFlirSystem() function through shell_exec() calls. Exploitation evidence was observed by the Shadowserver Foundation on 2026-01-06 (UTC).
CVE-2018-25154 1 Gnu 1 Barcode 2026-04-15 9.8 Critical
GNU Barcode 0.99 contains a buffer overflow vulnerability in its code 93 encoding process that allows attackers to trigger memory corruption. Attackers can exploit boundary errors during input file processing to potentially execute arbitrary code on the affected system.
CVE-2025-0356 2026-04-15 7.2 High
NEC Corporation Aterm WX1500HP Ver.1.4.2 and earlier and WX3600HP Ver.1.5.3 and earlier allows a attacker to execute arbitrary OS commands via the network.
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-0680 2026-04-15 9.8 Critical
Affected products contain a vulnerability in the device cloud rpc command handling process that could allow remote attackers to take control over arbitrary devices connected to the cloud.
CVE-2024-43688 2 Openbsd, Vixie 2 Openbsd, Cron 2026-04-15 7.3 High
cron/entry.c in vixie cron before 9cc8ab1, as used in OpenBSD 7.4 and 7.5, allows a heap-based buffer underflow and memory corruption. NOTE: this issue was introduced during a May 2023 refactoring.
CVE-2024-13089 2026-04-15 7.2 High
An OS command injection vulnerability within the update functionality may allow an authenticated administrator to execute unauthorized arbitrary OS commands. Users with administrative privileges may upload update packages to upgrade the versions of Nozomi Networks Guardian and CMC. While these updates are signed and their signatures are validated prior to installation, an improper signature validation check has been identified. This issue could potentially enable users to execute commands remotely on the appliance, thereby impacting confidentiality, integrity, and availability.
CVE-2023-49675 2026-04-15 7.8 High
An unauthenticated local attacker may trick a user to open corrupted project files to execute arbitrary code or crash the system due to an out-of-bounds write vulnerability.
CVE-2025-20295 1 Cisco 1 Unified Computing System Manager 2026-04-15 6 Medium
A vulnerability in the CLI of Cisco UCS Manager Software could allow an authenticated, local attacker with administrative privileges to read or create a file or overwrite any file on the file system of the underlying operating system of an affected device, including system files. &nbsp; This vulnerability is due to insufficient input validation of command arguments supplied by the user. An attacker could exploit this vulnerability by authenticating to a device and submitting crafted input to the affected command. A successful exploit could allow the attacker to read or create a file or overwrite any file on the file system of the underlying operating system of the affected device, including system files. To exploit this vulnerability, the attacker must have valid administrative credentials on the affected device.
CVE-2025-20294 1 Cisco 1 Unified Computing System Manager 2026-04-15 6.5 Medium
Multiple vulnerabilities in the CLI and web-based management interface of Cisco UCS Manager Software could allow an authenticated, remote attacker with administrative privileges to perform command injection attacks on an affected system and elevate privileges to root. &nbsp; These vulnerabilities are due to insufficient input validation of command arguments supplied by the user. An attacker could exploit these vulnerabilities by authenticating to a device and submitting crafted input to the affected commands. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system of the affected device with root-level privileges.
CVE-2024-43778 1 Takenaka Engineering 9 Ahd04t-a Firmware, Ahd08t-a Firmware, Ahd16t-a Firmware and 6 more 2026-04-15 8.8 High
OS command injection vulnerability in multiple digital video recorders provided by TAKENAKA ENGINEERING CO., LTD. allows a remote authenticated attacker to execute an arbitrary OS command on the device or alter the device settings.
CVE-2024-46658 1 Syrotech 1 Sy-gpon-8olt-l3 Firmware 2026-04-15 8 High
Syrotech SY-GOPON-8OLT-L3 v1.6.0_240629 was discovered to contain an authenticated command injection vulnerability.
CVE-2025-20161 2026-04-15 5.1 Medium
A vulnerability in the software upgrade process of Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches in standalone NX-OS mode could allow an authenticated, local attacker with valid Administrator credentials to execute a command injection attack on the underlying operating system of an affected device. This vulnerability is due to insufficient validation of specific elements within a software image. An attacker could exploit this vulnerability by installing a crafted image. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with root privileges.&nbsp; Note: Administrators should validate the hash of any software image before installation.
CVE-2025-62354 1 Cursor 1 Cursor 2026-04-15 9.8 Critical
Improper neutralization of special elements used in an OS command ('command injection') in Cursor allows an unauthorized attacker to execute commands that are outside of those specified in the allowlist, resulting in arbitrary code execution.
CVE-2024-45880 1 Motorola 1 Cx2l Firmware 2026-04-15 8 High
A command injection vulnerability exists in Motorola CX2L router v1.0.2 and below. The vulnerability is present in the SetStationSettings function. The system directly invokes the system function to execute commands for setting parameters such as MAC address without proper input filtering. This allows malicious users to inject and execute arbitrary commands.
CVE-2024-4582 2026-04-15 7.3 High
A vulnerability classified as critical has been found in Faraday GM8181 and GM828x up to 20240429. Affected is an unknown function of the component NTP Service. The manipulation of the argument ntp_srv leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. The identifier of this vulnerability is VDB-263304.
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).