| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability classified as critical has been found in GNU PSPP 82fb509fb2fedd33e7ac0c46ca99e108bb3bdffb. Affected is the function parse_variables_option of the file utilities/pspp-convert.c. The manipulation leads to out-of-bounds write. The attack needs to be approached locally. The exploit has been disclosed to the public and may be used. |
| A command injection is possible through the user interface, allowing arbitrary command execution as
the root user. oMG2000 running MGOS 3.15.1 or earlier is affected.
MG90 running MGOS 4.2.1 or earlier is affected. |
| OpenVPN 2.7_alpha1 through 2.7_beta1 on POSIX based platforms allows a remote authenticated server to inject shell commands via DNS variables when --dns-updown is in use |
| An OS command injection vulnerability exists in the OptiLink ONT1GEW GPON router firmware version V2.1.11_X101 Build 1127.190306 and earlier. The router’s web management interface fails to properly sanitize user input in the target_addr parameter of the formTracert and formPing administrative endpoints. An authenticated attacker can inject arbitrary operating system commands, which are executed with root privileges, leading to remote code execution. Successful exploitation enables full compromise of the device. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC. |
| Nuclei is a fast and customizable vulnerability scanner based on simple YAML based DSL. In affected versions it a way to execute code template without -code option and signature has been discovered. Some web applications inherit from Nuclei and allow users to edit and execute workflow files. In this case, users can execute arbitrary commands. (Although, as far as I know, most web applications use -t to execute). This issue has been addressed in version 3.3.0. Users are advised to upgrade. There are no known workarounds for this vulnerability. |
| SAP CommonCryptoLib does not perform necessary boundary checks during pre-authentication parsing of manipulated ASN.1 data over the network. This may result in memory corruption followed by an application crash, hence leading to a high impact on availability. There is no impact on confidentiality or integrity. |
| OS Command Injection in iSTAR Ultra products web application allows an authenticated attacker to gain even more privileged access ('root' user) to the device firmware. |
| Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in AE1021 firmware versions 2.0.10 and earlier and AE1021PE firmware versions 2.0.10 and earlier, which may allow a logged-in user to execute an arbitrary OS command using a crafted HTTP request. |
| Openfind's MailGates and MailAudit fail to properly filter user input when analyzing email attachments. An unauthenticated remote attacker can exploit this vulnerability to inject system commands and execute them on the remote server. |
| All versions of the package ggit are vulnerable to Command Injection via the fetchTags(branch) API, which allows user input to specify the branch to be fetched and then concatenates this string along with a git command which is then passed to the unsafe exec() Node.js child process API. |
| Command injection vulnerability in Asus RT-N15U 3.0.0.4.376_3754 allows a remote attacker to execute arbitrary code via the netstat function page. |
| An OS Command Injection vulnerability in Kiloview NDI allows a low-privileged user to execute arbitrary code remotely on the device with high privileges.
This issue affects Kiloview NDI N3, N3-s, N4, N20, N30, N40 and was fixed in Firmware version 2.02.0227 .
|
| OS command injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent unauthenticated attacker to execute arbitrary OS commands by sending a specially crafted request to the product. Affected products and versions are as follows: WRC-X3200GST3-B v1.25 and earlier, WRC-G01-W v1.24 and earlier, and WMC-X1800GST-B v1.41 and earlier. Note that WMC-X1800GST-B is also included in e-Mesh Starter Kit "WMC-2LX-B". |
| OS command injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent attacker with an administrative privilege to execute arbitrary OS commands by sending a specially crafted request to the product. Note that WMC-X1800GST-B is also included in e-Mesh Starter Kit "WMC-2LX-B". |
| Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root
This issue affects firmware versions before 24120701.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y). |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root
This issue affects all Iocharger AC EV charger models on a firmware version before 25010801.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| Authenticated Remote Code Execution in Altalink, Versalink & WorkCentre Products. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |