| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| OS command injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent unauthenticated attacker to execute arbitrary OS commands by sending a specially crafted request to the product. Affected products and versions are as follows: WRC-X3200GST3-B v1.25 and earlier, WRC-G01-W v1.24 and earlier, and WMC-X1800GST-B v1.41 and earlier. Note that WMC-X1800GST-B is also included in e-Mesh Starter Kit "WMC-2LX-B". |
| OS command injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent attacker with an administrative privilege to execute arbitrary OS commands by sending a specially crafted request to the product. Note that WMC-X1800GST-B is also included in e-Mesh Starter Kit "WMC-2LX-B". |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services. |
| Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y). |
| Due to the improper handling of batch files in child_process.spawn / child_process.spawnSync, a malicious command line argument can inject arbitrary commands and achieve code execution even if the shell option is not enabled. |
| Hikvision CSMP (Comprehensive Security Management Platform) iSecure Center through 2024-08-01 allows execution of a command within $( ) in /center/api/installation/detection JSON data, as exploited in the wild in 2024 and 2025. |
| Operating system command injection vulnerability in Planet IGS-4215-16T2S, affecting firmware version 1.305b210528. An authenticated attacker could execute arbitrary code on the remote host by exploiting IP address functionality. |
| An issue discovered in the DeviceIoControl component in ASUS Fan_Xpert before v.10013 allows an attacker to execute arbitrary code via crafted IOCTL requests. |
| The specific function parameter of ASUS Download Master does not properly filter user input. An unauthenticated remote attacker with administrative privileges can exploit this vulnerability to execute arbitrary system commands on the device. |
| OS command injection vulnerability exists in AIPHONE IX SYSTEM and IXG SYSTEM. A network-adjacent authenticated attacker may execute an arbitrary OS command with root privileges by sending a specially crafted request. |
| The iSherlock developed by Hgiga has an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the server. This vulnerability has already been exploited. Please update immediately. |
| Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in NCP-HG100 1.4.48.16 and earlier. If exploited, a remote attacker who has obtained the authentication information to log in to the management page of the product may execute an arbitrary OS command with root privileges. |
| An Authenticated Remote Code Execution (RCE) vulnerability affects the TP-Link Archer router series. A vulnerability exists in the "tmp_get_sites" function of the HomeShield functionality provided by TP-Link. This vulnerability is still exploitable without the activation of the HomeShield functionality. |
| An issue in Infotel Conseil GLPI v.10.X.X and after allows a remote attacker to execute arbitrary code via the insufficient validation of user-supplied input. |
| A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0011). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22974) |
|
Improper Input Validation vulnerability in Samsung Open Source escargot JavaScript engine allows Overflow Buffers.
However, it occurs in the test code and does not include in the release.
This issue affects escargot: 4.0.0.
|
| A Segmentation Fault issue discovered in
Samsung Open Source Escargot JavaScript engine
allows remote attackers to cause a denial of service via crafted input.
This issue affects Escargot: 4.0.0.
|
| Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege. |
| Out-Of-Bounds Write and Type Confusion vulnerabilities exist in the file reading procedure in eDrawings from Release SOLIDWORKS 2023 through Release SOLIDWORKS 2024. These vulnerabilities could allow an attacker to execute arbitrary code while opening a specially crafted DWG or DXF. NOTE: this vulnerability was SPLIT from CVE-2024-1847. |