Search Results (1914 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-39967 2026-04-15 6.5 Medium
Insecure permissions in Aginode GigaSwitch v5 allows attackers to access sensitive information via using the SCP command.
CVE-2024-41171 1 Siemens 3 Sinumerik 828d Firmware, Sinumerik 840d Sl Firmware, Sinumerik One Firmware 2026-04-15 8.8 High
A vulnerability has been identified in SINUMERIK 828D V4 (All versions), SINUMERIK 828D V5 (All versions < V5.24), SINUMERIK 840D sl V4 (All versions), SINUMERIK ONE (All versions < V6.24). Affected devices do not properly enforce access restrictions to scripts that are regularly executed by the system with elevated privileges. This could allow an authenticated local attacker to escalate their privileges in the underlying system.
CVE-2024-41820 2026-04-15 6 Medium
Kubean is a cluster lifecycle management toolchain based on kubespray and other cluster LCM engine. The ClusterRole has `*` verbs of `*` resources. If a malicious user can access the worker node which has kubean's deployment, he/she can abuse these excessive permissions to do whatever he/she likes to the whole cluster, resulting in a cluster-level privilege escalation. This issue has been addressed in release version 0.18.0. Users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2024-45841 2026-04-15 N/A
Incorrect permission assignment for critical resource issue exists in UD-LT1 firmware Ver.2.1.9 and earlier and UD-LT1/EX firmware Ver.2.1.9 and earlier. If an attacker with the guest account of the affected products accesses a specific file, the information containing credentials may be obtained.
CVE-2024-46881 1 Gradle 1 Enterprise 2026-04-15 7.1 High
Develocity (formerly Gradle Enterprise) before 2024.1.8 has Incorrect Access Control. Project-level access control configuration was introduced in Enterprise Config schema version 8. Migration functionality from schema version 8 to versions 9 and 10 (in affected vulnerable versions) does not include the projects section of the configuration. This leads to all of the project settings being reset to their defaults when the old schema is loaded. In the case of projects.enabled, the default is false. Thus, using an enterprise config v8 results in Project level access control being disabled, even if it was previously enabled, and previously restricted project information disclosed. Most commonly, this occurs when a Develocity instance is upgraded from an earlier version. Specifically, this occurs if: Develocity 2023.3.X is upgraded to 2023.4.X; Develocity 2023.3.X is upgraded to 2024.1.X up to and including 2024.1.7; or Develocity 2023.4.X is upgraded to 2024.1.X up to and including 2024.1.7. The flaw does not occur when upgrading to a fixed version. An upgrade can only be triggered via administrator access, and cannot be forced by an external attacker.
CVE-2024-50590 1 Hasomed 1 Elefant 2026-04-15 7.8 High
Attackers with local access to the medical office computer can escalate their Windows user privileges to "NT AUTHORITY\SYSTEM" by overwriting one of two Elefant service binaries with weak permissions. The default installation directory of Elefant is "C:\Elefant1" which is writable for all users. In addition, the Elefant installer registers two Firebird database services which are running as “NT AUTHORITY\SYSTEM”.  Path: C:\Elefant1\Firebird_2\bin\fbserver.exe Path: C:\Elefant1\Firebird_2\bin\fbguard.exe Both service binaries are user writable. This means that a local attacker can rename one of the service binaries, replace the service executable with a new executable, and then restart the system. Once the system has rebooted, the new service binary is executed as "NT AUTHORITY\SYSTEM".
CVE-2024-5163 1 Tecno 1 Com.transsion.carlcare 2026-04-15 9.8 Critical
Improper permission settings for mobile applications (com.transsion.carlcare) may lead to user password and account security risks.
CVE-2024-6619 2 Aveva, Ocean Data Systems 2 Reports For Operations 2023, Dream Report 2023 2026-04-15 N/A
In Ocean Data Systems Dream Report, an incorrect permission vulnerability could allow a local unprivileged attacker to escalate their privileges and could cause a denial-of-service.
CVE-2024-6780 2026-04-15 3.3 Low
Improper permission control in the mobile application (com.android.server.telecom) may lead to user information security risks.
CVE-2025-0374 1 Freebsd 1 Freebsd 2026-04-15 6.5 Medium
When etcupdate encounters conflicts while merging files, it saves a version containing conflict markers in /var/db/etcupdate/conflicts. This version does not preserve the mode of the input file, and is world-readable. This applies to files that would normally have restricted visibility, such as /etc/master.passwd. An unprivileged local user may be able to read encrypted root and user passwords from the temporary master.passwd file created in /var/db/etcupdate/conflicts. This is possible only when conflicts within the password file arise during an update, and the unprotected file is deleted when conflicts are resolved.
CVE-2025-0590 2026-04-15 7.5 High
Improper permission settings for mobile applications (com.transsion.carlcare) may lead to information leakage risk.
CVE-2025-0758 1 Hitachi 1 Vantara Pentaho Business Analytics Server 2026-04-15 6.1 Medium
Overview  The product specifies permissions for a security-critical resource in a way that allows that resource to be read or modified by unintended actors. (CWE-732)  Description  Hitachi Vantara Pentaho Business Analytics Server prior to versions 10.2.0.2, including 9.3.x and 8.3.x, is installed with Karaf JMX beans enabled and accessible by default.  Impact  When the vulnerability is leveraged, a user with local execution privileges can access functionality exposed by Karaf beans contained in the product.
CVE-2019-25343 1 Vm3max 1 Nextvpn 2026-04-15 7.8 High
NextVPN 4.10 contains an insecure file permissions vulnerability that allows local users to modify executable files with full access rights. Attackers can replace system executables with malicious files to gain SYSTEM or Administrator privileges through unauthorized file modification.
CVE-2019-25245 2026-04-15 8.8 High
Ross Video DashBoard 8.5.1 contains an elevation of privileges vulnerability that allows authenticated users to modify executable files due to improper permission settings. Attackers can exploit the 'M' or 'C' flags for 'Authenticated Users' group to replace the DashBoard.exe binary with a malicious executable.
CVE-2025-2098 2026-04-15 N/A
Fast CAD Reader application on MacOS was found to be installed with incorrect file permissions (rwxrwxrwx). This is inconsistent with standard macOS security practices, where applications should have drwxr-xr-x permissions. Incorrect permissions allow for Dylib Hijacking. Guest account, other users and applications can exploit this vulnerability for privilege escalation. This issue affects Fast CAD Reader in possibly all versions since the vendor has not responded to our messages. The tested version was 4.1.5
CVE-2025-68462 1 Debian 1 Freedombox 2026-04-15 3.2 Low
Freedombox before 25.17.1 does not set proper permissions for the backups-data directory, allowing the reading of dump files of databases.
CVE-2023-32190 1 Suse 1 Opensuse Tumbleweed 2026-04-15 7.8 High
mlocate's %post script allows RUN_UPDATEDB_AS user to make arbitrary files world readable by abusing insecure file operations that run with root privileges.
CVE-2025-61969 1 Amd 1 Amd Uprof 2026-04-15 N/A
Incorrect permission assignment in AMD µProf may allow a local user-privileged attacker to achieve privilege escalation, potentially resulting in arbitrary code execution.
CVE-2025-50675 2026-04-15 7.8 High
GPMAW 14, a bioinformatics software, has a critical vulnerability related to insecure file permissions in its installation directory. The directory is accessible with full read, write, and execute permissions for all users, allowing unprivileged users to manipulate files within the directory, including executable files like GPMAW3.exe, Fragment.exe, and the uninstaller GPsetup64_17028.exe. An attacker with user-level access can exploit this misconfiguration by replacing or modifying the uninstaller (GPsetup64_17028.exe) with a malicious version. While the application itself runs in the user's context, the uninstaller is typically executed with administrative privileges when an administrator attempts to uninstall the software. By exploiting this flaw, an attacker could gain administrative privileges and execute arbitrary code in the context of the admin, resulting in privilege escalation.
CVE-2025-42997 2026-04-15 6.6 Medium
Under certain conditions, SAP Gateway Client allows a high-privileged user to access restricted information beyond the scope of the application. Due to the possibility of influencing application behavior or performance through misuse of the exposed data, this may potentially lead to low impact on confidentiality, integrity, and availability.