Export limit exceeded: 409359 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (2353 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2007-1917 | 8 Apple, Hp, Ibm and 5 more | 11 Macos, Hp-ux, Tru64 and 8 more | 2026-04-23 | N/A |
| Buffer overflow in the SYSTEM_CREATE_INSTANCE function in the SAP RFC Library 6.40 and 7.00 before 20061211 allows remote attackers to execute arbitrary code via unspecified vectors. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended. | ||||
| CVE-2007-1918 | 8 Apple, Hp, Ibm and 5 more | 11 Macos, Hp-ux, Tru64 and 8 more | 2026-04-23 | N/A |
| The RFC_SET_REG_SERVER_PROPERTY function in the SAP RFC Library 6.40 and 7.00 before 20070109 implements an option for exclusive access to an RFC server, which allows remote attackers to cause a denial of service (client lockout) via unspecified vectors. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended. | ||||
| CVE-2017-5689 | 3 Hpe, Intel, Siemens | 71 Proliant Ml10 Gen9 Server, Proliant Ml10 Gen9 Server Firmware, Active Management Technology Firmware and 68 more | 2026-04-22 | 9.8 Critical |
| An unprivileged network attacker could gain system privileges to provisioned Intel manageability SKUs: Intel Active Management Technology (AMT) and Intel Standard Manageability (ISM). An unprivileged local attacker could provision manageability features gaining unprivileged network or local system privileges on Intel manageability SKUs: Intel Active Management Technology (AMT), Intel Standard Manageability (ISM), and Intel Small Business Technology (SBT). | ||||
| CVE-2017-0148 | 2 Microsoft, Siemens | 27 Server Message Block, Windows 10 1507, Windows 10 1511 and 24 more | 2026-04-22 | 8.1 High |
| The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to execute arbitrary code via crafted packets, aka "Windows SMB Remote Code Execution Vulnerability." This vulnerability is different from those described in CVE-2017-0143, CVE-2017-0144, CVE-2017-0145, and CVE-2017-0146. | ||||
| CVE-2017-0147 | 2 Microsoft, Siemens | 26 Windows 10 1507, Windows 10 1511, Windows 10 1607 and 23 more | 2026-04-22 | 7.5 High |
| The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to obtain sensitive information from process memory via a crafted packets, aka "Windows SMB Information Disclosure Vulnerability." | ||||
| CVE-2017-0146 | 2 Microsoft, Siemens | 27 Server Message Block, Windows 10 1507, Windows 10 1511 and 24 more | 2026-04-22 | 8.8 High |
| The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to execute arbitrary code via crafted packets, aka "Windows SMB Remote Code Execution Vulnerability." This vulnerability is different from those described in CVE-2017-0143, CVE-2017-0144, CVE-2017-0145, and CVE-2017-0148. | ||||
| CVE-2017-0145 | 2 Microsoft, Siemens | 27 Server Message Block, Windows 10 1507, Windows 10 1511 and 24 more | 2026-04-22 | 8.8 High |
| The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to execute arbitrary code via crafted packets, aka "Windows SMB Remote Code Execution Vulnerability." This vulnerability is different from those described in CVE-2017-0143, CVE-2017-0144, CVE-2017-0146, and CVE-2017-0148. | ||||
| CVE-2017-0144 | 2 Microsoft, Siemens | 27 Server Message Block, Windows 10 1507, Windows 10 1511 and 24 more | 2026-04-22 | 8.8 High |
| The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to execute arbitrary code via crafted packets, aka "Windows SMB Remote Code Execution Vulnerability." This vulnerability is different from those described in CVE-2017-0143, CVE-2017-0145, CVE-2017-0146, and CVE-2017-0148. | ||||
| CVE-2017-0143 | 3 Microsoft, Philips, Siemens | 28 Server Message Block, Windows 10 1507, Windows 10 1511 and 25 more | 2026-04-22 | 8.8 High |
| The SMBv1 server in Microsoft Windows Vista SP2; Windows Server 2008 SP2 and R2 SP1; Windows 7 SP1; Windows 8.1; Windows Server 2012 Gold and R2; Windows RT 8.1; and Windows 10 Gold, 1511, and 1607; and Windows Server 2016 allows remote attackers to execute arbitrary code via crafted packets, aka "Windows SMB Remote Code Execution Vulnerability." This vulnerability is different from those described in CVE-2017-0144, CVE-2017-0145, CVE-2017-0146, and CVE-2017-0148. | ||||
| CVE-2014-0160 | 13 Broadcom, Canonical, Debian and 10 more | 37 Symantec Messaging Gateway, Ubuntu Linux, Debian Linux and 34 more | 2026-04-21 | 7.5 High |
| The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys, related to d1_both.c and t1_lib.c, aka the Heartbleed bug. | ||||
| CVE-2016-8562 | 1 Siemens | 4 Simatic Cp 1543-1, Simatic Cp 1543-1 Firmware, Siplus Net Cp 1543-1 and 1 more | 2026-04-21 | 7.5 High |
| A vulnerability has been identified in SIMATIC CP 1543-1 (All versions < V2.0.28), SIPLUS NET CP 1543-1 (All versions < V2.0.28). Under special conditions it was possible to write SNMP variables on port 161/udp which should be read-only and should only be configured with TIA-Portal. A write to these variables could reduce the availability or cause a denial-of-service. | ||||
| CVE-2026-23715 | 1 Siemens | 2 Simcenter Femap, Simcenter Nastran | 2026-04-18 | 7.8 High |
| A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds write vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process. | ||||
| CVE-2026-23716 | 1 Siemens | 2 Simcenter Femap, Simcenter Nastran | 2026-04-17 | 7.8 High |
| A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process. | ||||
| CVE-2026-23717 | 1 Siemens | 2 Simcenter Femap, Simcenter Nastran | 2026-04-17 | 7.8 High |
| A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process. | ||||
| CVE-2026-23718 | 1 Siemens | 2 Simcenter Femap, Simcenter Nastran | 2026-04-17 | 7.8 High |
| A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process. | ||||
| CVE-2026-23719 | 1 Siemens | 2 Simcenter Femap, Simcenter Nastran | 2026-04-17 | 7.8 High |
| A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process. | ||||
| CVE-2026-23720 | 1 Siemens | 2 Simcenter Femap, Simcenter Nastran | 2026-04-17 | 7.8 High |
| A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process. | ||||
| CVE-2026-25655 | 1 Siemens | 2 Sinec-nms, Sinec Nms | 2026-04-17 | 7.8 High |
| A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP2). The affected application permits improper modification of a configuration file by a low-privileged user. This could allow an attacker to load malicious DLLs, potentially leading to arbitrary code execution with administrative privilege.(ZDI-CAN-28107) | ||||
| CVE-2026-33892 | 1 Siemens | 2 Industrial Edge Management Pro, Industrial Edge Management Virtual | 2026-04-17 | 7.1 High |
| A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device. Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected. | ||||
| CVE-2025-40745 | 1 Siemens | 8 Simcenter 3d, Simcenter Femap, Simcenter Star-ccm\+ and 5 more | 2026-04-17 | 3.7 Low |
| A vulnerability has been identified in Siemens Software Center (All versions < V3.5.8.2), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Simcenter STAR-CCM+ (All versions < V2602), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Tecnomatix Plant Simulation (All versions < V2504.0008). Affected applications do not properly validate client certificates to connect to Analytics Service endpoint. This could allow an unauthenticated remote attacker to perform man in the middle attacks. | ||||