Search Results (452 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-22017 2 Nodejs, Redhat 2 Nodejs, Enterprise Linux 2026-04-15 7.3 High
setuid() does not affect libuv's internal io_uring operations if initialized before the call to setuid(). This allows the process to perform privileged operations despite presumably having dropped such privileges through a call to setuid(). This vulnerability affects all users using version greater or equal than Node.js 18.18.0, Node.js 20.4.0 and Node.js 21.
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-8907 2026-04-15 7 High
A vulnerability was found in H3C M2 NAS V100R006. Affected by this vulnerability is an unknown functionality of the component Webserver Configuration. The manipulation leads to execution with unnecessary privileges. An attack has to be approached locally. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor explains: "[T]he device only has configuration files and does not actually have boa functionality. It is impossible to access or upload files anonymously to the device through boa services". This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2025-62876 1 Kde 1 Kde 2026-04-15 N/A
A Execution with Unnecessary Privileges vulnerability in lightdm-kde-greeter allows escalation from the service user to root.This issue affects lightdm-kde-greeter. before 6.0.4.
CVE-2025-3925 2026-04-15 7.8 High
BrightSign players running BrightSign OS series 4 prior to v8.5.53.1 or series 5 prior to v9.0.166 contain an execution with unnecessary privileges vulnerability, allowing for privilege escalation on the device once code execution has been obtained.
CVE-2024-0073 2026-04-15 7.8 High
NVIDIA GPU Display Driver for Windows contains a vulnerability in the kernel mode layer when the driver is performing an operation at a privilege level that is higher than the minimum level required. A successful exploit of this vulnerability may lead to code execution, denial of service, escalation of privileges, information disclosure, and data tampering.
CVE-2024-11075 1 Sick Ag 1 Incoming Goods Suite 2026-04-15 8.8 High
A vulnerability in the Incoming Goods Suite allows a user with unprivileged access to the underlying system (e.g. local or via SSH) a privilege escalation to the administrative level due to the usage of component vendor Docker images running with root permissions. Exploiting this misconfiguration leads to the fact that an attacker can gain administrative control. over the whole system.
CVE-2024-13090 2026-04-15 7 High
A privilege escalation vulnerability may enable a service account to elevate its privileges. The sudo rules configured for a local service account were excessively permissive, potentially allowing administrative access if a malicious actor could execute arbitrary commands as that account. It is important to note that no such vector has been identified in this instance.
CVE-2024-21924 2026-04-15 8.2 High
SMM callout vulnerability within the AmdPlatformRasSspSmm driver could allow a ring 0 attacker to modify boot services handlers, potentially resulting in arbitrary code execution.
CVE-2024-28139 2026-04-15 8.8 High
The www-data user can elevate its privileges because sudo is configured to allow the execution of the mount command as root without a password. Therefore, the privileges can be escalated to the root user. The risk has been accepted by the vendor and won't be fixed in the near future.
CVE-2024-28140 2026-04-15 6.1 Medium
The scanner device boots into a kiosk mode by default and opens the Scan2Net interface in a browser window. This browser is run with the permissions of the root user. There are also several other applications running as root user. This can be confirmed by running "ps aux" as the root user and observing the output.
CVE-2024-3498 2026-04-15 7.8 High
Attackers can then execute malicious files by enabling certain services of the printer via the web configuration page and elevate its privileges to root. As for the affected products/models/versions, see the reference URL.
CVE-2025-3364 1 Hgiga 1 Powerstation 2026-04-15 6.7 Medium
The SSH service of PowerStation from HGiga has a Chroot Escape vulnerability, allowing attackers with root privileges to bypass chroot restrictions and access the entire file system.
CVE-2025-23181 2026-04-15 8 High
CWE-250: Execution with Unnecessary Privileges
CVE-2025-1977 1 Moxa 2 Nport 6100-g2 Series, Nport 6200-g2 Series 2026-04-15 N/A
The NPort 6100-G2/6200-G2 Series is affected by an execution with unnecessary privileges vulnerability (CVE-2025-1977) that allows an authenticated user with read-only access to perform unauthorized configuration changes through the MCC (Moxa CLI Configuration) tool. The issue can be exploited remotely over the network with low-attack complexity and no user interaction but requires specific system conditions or configurations to be present. Successful exploitation may result in changes to device settings that were not intended to be permitted for the affected user role, potentially leading to a high impact on the confidentiality, integrity, and availability of the device. No impact on other systems has been identified.
CVE-2025-24331 2026-04-15 6.4 Medium
The Single RAN baseband OAM service is intended to run as an unprivileged service. However, it initially starts with root privileges and assigns certain capabilities before dropping to an unprivileged level. The capabilities retained from the root period are considered extensive after the privilege drop and, in theory, could potentially allow actions beyond the intended scope of the OAM service. These actions could include gaining root privileges, accessing root-owned files, modifying them as the file owner, and then returning them to root ownership. This issue has been corrected starting from release 24R1-SR 0.2 MP and later. Beginning with release 24R1-SR 0.2 MP, the OAM service software capabilities are restricted to the minimum necessary.
CVE-2026-4498 1 Elastic 1 Kibana 2026-04-14 7.7 High
Execution with Unnecessary Privileges (CWE-250) in Kibana’s Fleet plugin debug route handlers can lead reading index data beyond their direct Elasticsearch RBAC scope via Privilege Abuse (CAPEC-122). This requires an authenticated Kibana user with Fleet sub-feature privileges (such as agents, agent policies, and settings management).
CVE-2026-1346 1 Ibm 4 Security Verify Access, Security Verify Access Container, Verify Identity Access and 1 more 2026-04-10 9.3 Critical
IBM Verify Identity Access Container 11.0 through 11.0.2 and IBM Security Verify Access Container 10.0 through 10.0.9.1 and IBM Verify Identity Access 11.0 through 11.0.2 and IBM Security Verify Access 10.0 through 10.0.9.1 could allow a locally authenticated user to escalate their privileges to root due to execution with unnecessary privileges than required.