Vulnerabilities (CVE)

Filtered by vendor Philips Subscribe
Filtered by product Clinical Collaboration Platform
Total 8 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2025-27955 1 Philips 1 Clinical Collaboration Platform 2025-06-13 N/A 6.5 MEDIUM
Clinical Collaboration Platform 12.2.1.5 has a weak logout system where the session token remains valid after logout and allows a remote attacker to obtain sensitive information and execute arbitrary code.
CVE-2025-27954 1 Philips 1 Clinical Collaboration Platform 2025-06-13 N/A 6.5 MEDIUM
An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the usertoken function of default.aspx.
CVE-2025-27953 1 Philips 1 Clinical Collaboration Platform 2025-06-13 N/A 6.5 MEDIUM
An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the session management component.
CVE-2020-16247 1 Philips 1 Clinical Collaboration Platform 2025-06-04 3.6 LOW 6.8 MEDIUM
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.
CVE-2020-16200 1 Philips 1 Clinical Collaboration Platform 2025-06-04 3.3 LOW 6.5 MEDIUM
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources.
CVE-2020-16198 1 Philips 1 Clinical Collaboration Platform 2025-06-04 5.8 MEDIUM 5.0 MEDIUM
When an attacker claims to have a given identity, Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not prove or insufficiently proves the claim is correct.
CVE-2020-14525 1 Philips 1 Clinical Collaboration Platform 2025-06-04 2.7 LOW 3.5 LOW
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users.
CVE-2020-14506 1 Philips 1 Clinical Collaboration Platform 2025-06-04 4.3 MEDIUM 3.4 LOW
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.