Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Filtered by product Ac18 Firmware
Total 103 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-35201 1 Tenda 2 Ac18, Ac18 Firmware 2026-07-09 N/A 9.8 CRITICAL
Tenda-AC18 V15.03.05.05 was discovered to contain a remote command execution (RCE) vulnerability.
CVE-2026-31255 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 9.8 CRITICAL
A command injection vulnerability exists in Tenda AC18 V15.03.05.05_multi. The vulnerability is located in the /goform/SetSambaCfg interface, where improper handling of the guestuser parameter allows attackers to execute arbitrary system commands.
CVE-2025-9023 1 Tenda 4 Ac18, Ac18 Firmware, Ac7 and 1 more 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-8182 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 5.1 MEDIUM 5.6 MEDIUM
A vulnerability has been found in Tenda AC18 15.03.05.19 and classified as problematic. This vulnerability affects unknown code of the file /etc_ro/smb.conf of the component Samba. The manipulation leads to weak password requirements. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used.
CVE-2025-63835 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 8.8 HIGH
A stack-based buffer overflow vulnerability was discovered in Tenda AC18 v15.03.05.05_multi. The vulnerability exists in the guestSsid parameter of the /goform/WifiGuestSet interface. Remote attackers can exploit this vulnerability by sending oversized data to the guestSsid parameter, leading to denial of service (device crash) or potential remote code execution.
CVE-2025-63834 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 5.4 MEDIUM
A stored cross-site scripting (XSS) vulnerability was discovered in Tenda AC18 v15.03.05.05_multi. The vulnerability exists in the ssid parameter of the wireless settings. Remote attackers can inject malicious payloads that execute when any user visits the router's homepage.
CVE-2025-60663 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 7.5 HIGH
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the wanMTU parameter in the fromAdvSetMacMtuWan function.
CVE-2025-60662 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 7.5 HIGH
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the wanSpeed parameter in the fromAdvSetMacMtuWan function.
CVE-2025-60661 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 5.3 MEDIUM
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the cloneType parameter in the fromAdvSetMacMtuWan function.
CVE-2025-60660 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 7.5 HIGH
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the mac parameter in the fromAdvSetMacMtuWan function.
CVE-2025-5609 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-5608 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formsetreboottimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-5607 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-5606 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 6.5 MEDIUM 6.3 MEDIUM
A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetIptv of the file /goform/SetIPTVCfg. The manipulation of the argument list leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-14993 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was detected in Tenda AC18 15.03.05.05. This affects the function sprintf of the file /goform/SetDlnaCfg of the component HTTP Request Handler. The manipulation of the argument scanList results in stack-based buffer overflow. The attack can be executed remotely. The exploit is now public and may be used.
CVE-2025-14992 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A security vulnerability has been detected in Tenda AC18 15.03.05.05. The impacted element is the function strcpy of the file /goform/GetParentControlInfo of the component HTTP Request Handler. The manipulation of the argument mac leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used.
CVE-2025-11328 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was detected in Tenda AC18 15.03.05.19(6318). This issue affects some unknown processing of the file /goform/SetDDNSCfg. The manipulation of the argument ddnsEn results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is now public and may be used.
CVE-2025-11327 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A security vulnerability has been detected in Tenda AC18 15.03.05.19(6318). This vulnerability affects unknown code of the file /goform/SetUpnpCfg. The manipulation of the argument upnpEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used.
CVE-2025-11326 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A weakness has been identified in Tenda AC18 15.03.05.19(6318). This affects an unknown part of the file /goform/WifiMacFilterSet. Executing a manipulation of the argument wifi_chkHz can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been made available to the public and could be used for attacks.
CVE-2025-11325 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A security flaw has been discovered in Tenda AC18 15.03.05.19(6318). Affected by this issue is some unknown functionality of the file /goform/fast_setting_pppoe_set. Performing a manipulation of the argument Username results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks.