Filtered by vendor Tenda
Subscribe
Total
1846 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2023-37710 | 1 Tenda | 4 Ac10, Ac10 Firmware, Ac1206 and 1 more | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function. | |||||
| CVE-2023-37707 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. | |||||
| CVE-2023-37706 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function. | |||||
| CVE-2023-37705 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromAddressNat function. | |||||
| CVE-2023-37704 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. | |||||
| CVE-2023-37703 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. | |||||
| CVE-2023-37702 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function. | |||||
| CVE-2023-37701 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. | |||||
| CVE-2023-37700 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function. | |||||
| CVE-2023-37144 | 2 Tenda, Tendacn | 2 Ac10, Ac10 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac. | |||||
| CVE-2023-36103 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Command Injection vulnerability in goform/SetIPTVCfg interface of Tenda AC15 V15.03.05.20 allows remote attackers to run arbitrary commands via crafted POST request. | |||||
| CVE-2023-34571 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2026-06-17 | N/A | 6.7 MEDIUM |
| Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter shareSpeed at /goform/WifiGuestSet. | |||||
| CVE-2023-34570 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2026-06-17 | N/A | 6.7 MEDIUM |
| Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter devName at /goform/SetOnlineDevName. | |||||
| CVE-2023-34569 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2026-06-17 | N/A | 6.7 MEDIUM |
| Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList. | |||||
| CVE-2023-34568 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2026-06-17 | N/A | 6.7 MEDIUM |
| Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet. | |||||
| CVE-2023-34567 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2026-06-17 | N/A | 6.7 MEDIUM |
| Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg. | |||||
| CVE-2023-34566 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo. | |||||
| CVE-2023-33675 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function. | |||||
| CVE-2023-33673 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function. | |||||
| CVE-2023-33672 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function. | |||||
