Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Total 1901 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-33726 1 Siemens 1 Sinec Nms 2024-11-21 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system allows to download arbitrary files under a user controlled path and does not correctly check if the relative path is still within the intended target directory.
CVE-2021-33725 1 Siemens 1 Sinec Nms 2024-11-21 5.0 MEDIUM 9.1 CRITICAL
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system allows to delete arbitrary files or directories under a user controlled path and does not correctly check if the relative path is still within the intended target directory.
CVE-2021-33724 1 Siemens 1 Sinec Nms 2024-11-21 5.0 MEDIUM 9.1 CRITICAL
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system contains an Arbitrary File Deletion vulnerability that possibly allows to delete an arbitrary file or directory under a user controlled path.
CVE-2021-33723 1 Siemens 1 Sinec Nms 2024-11-21 4.0 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). An authenticated attacker could change the user profile of any user without proper authorization. With this, the attacker could change the password of any user in the affected system.
CVE-2021-33722 1 Siemens 1 Sinec Nms 2024-11-21 4.0 MEDIUM 4.9 MEDIUM
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system has a Path Traversal vulnerability when exporting a firmware container. With this a privileged authenticated attacker could create arbitrary files on an affected system.
CVE-2021-33721 1 Siemens 1 Sinec Network Management System 2024-11-21 9.0 HIGH 7.2 HIGH
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2). The affected application incorrectly neutralizes special elements when creating batch operations which could lead to command injection. An authenticated remote attacker with administrative privileges could exploit this vulnerability to execute arbitrary code on the system with system privileges.
CVE-2021-33720 1 Siemens 3 Siprotec 5 With Cpu Variant Cp050, Siprotec 5 With Cpu Variant Cp100, Siprotec 5 With Cpu Variant Cp300 2024-11-21 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Specially crafted packets sent to port 4443/tcp could cause a Denial-of-Service condition.
CVE-2021-33719 1 Siemens 3 Siprotec 5 With Cpu Variant Cp050, Siprotec 5 With Cpu Variant Cp100, Siprotec 5 With Cpu Variant Cp300 2024-11-21 7.5 HIGH 9.8 CRITICAL
A vulnerability has been identified in SIPROTEC 5 relays with CPU variants CP050 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP100 (All versions < V8.80), SIPROTEC 5 relays with CPU variants CP300 (All versions < V8.80). Specially crafted packets sent to port 4443/tcp could cause a Denial-of-Service condition or potential remote code execution.
CVE-2021-33718 1 Siemens 1 Mendix 2024-11-21 3.5 LOW 5.3 MEDIUM
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.22), Mendix Applications using Mendix 8 (All versions < V8.18.7), Mendix Applications using Mendix 9 (All versions < V9.3.0). Write access checks of attributes of an object could be bypassed, if user has a write permissions to the first attribute of this object.
CVE-2021-33717 1 Siemens 2 Jt2go, Teamcenter Visualization 2024-11-21 4.3 MEDIUM 5.5 MEDIUM
A vulnerability has been identified in JT2Go (All versions < V13.2.0.1), Teamcenter Visualization (All versions < V13.2.0.1). When parsing specially crafted CGM Files, a NULL pointer deference condition could cause the application to crash. The application must be restarted to restore the service. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application.
CVE-2021-33716 1 Siemens 4 Simatic Cp 1543-1, Simatic Cp 1543-1 Firmware, Simatic Cp 1545-1 and 1 more 2024-11-21 3.3 LOW 6.5 MEDIUM
A vulnerability has been identified in SIMATIC CP 1543-1 (incl. SIPLUS variants) (All versions < V3.0), SIMATIC CP 1545-1 (All versions < V1.1). An attacker with access to the subnet of the affected device could retrieve sensitive information stored in cleartext.
CVE-2021-33715 1 Siemens 1 Jt Utilities 2024-11-21 2.1 LOW 5.5 MEDIUM
A vulnerability has been identified in JT Utilities (All versions < V13.0.2.0). When parsing specially crafted JT files, a race condition could cause an object to be released before being operated on, leading to NULL pointer deference condition and causing the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application.
CVE-2021-33714 1 Siemens 1 Jt Utilities 2024-11-21 2.1 LOW 5.5 MEDIUM
A vulnerability has been identified in JT Utilities (All versions < V13.0.2.0). When parsing specially crafted JT files, a missing check for the validity of an iterator leads to NULL pointer deference condition, causing the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application.
CVE-2021-33713 1 Siemens 1 Jt Utilities 2024-11-21 2.1 LOW 5.5 MEDIUM
A vulnerability has been identified in JT Utilities (All versions < V13.0.2.0). When parsing specially crafted JT files, a hash function is called with an incorrect argument leading the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application.
CVE-2021-33711 1 Siemens 1 Teamcenter Active Workspace 2024-11-21 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions < V4.3.9), Teamcenter Active Workspace V5.0 (All versions < V5.0.7), Teamcenter Active Workspace V5.1 (All versions < V5.1.4). The affected application allows verbose error messages which allow leaking of sensitive information, such as full paths.
CVE-2021-33710 1 Siemens 1 Teamcenter Active Workspace 2024-11-21 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions < V4.3.9), Teamcenter Active Workspace V5.0 (All versions < V5.0.7), Teamcenter Active Workspace V5.1 (All versions < V5.1.4). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected devices that could allow an attacker to execute malicious JavaScript code by tricking users into accessing a malicious link.
CVE-2021-33709 1 Siemens 1 Teamcenter Active Workspace 2024-11-21 4.0 MEDIUM 4.3 MEDIUM
A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions < V4.3.9), Teamcenter Active Workspace V5.0 (All versions < V5.0.7), Teamcenter Active Workspace V5.1 (All versions < V5.1.4). By sending malformed requests, a remote attacker could leak an application token due to an error not properly handled by the system.
CVE-2021-33627 2 Insyde, Siemens 29 Insydeh2o, Simatic Field Pg M5, Simatic Field Pg M5 Firmware and 26 more 2024-11-21 7.2 HIGH 8.2 HIGH
An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
CVE-2021-33626 2 Insyde, Siemens 33 Insydeh2o, Ruggedcom Apr1808, Ruggedcom Apr1808 Firmware and 30 more 2024-11-21 4.6 MEDIUM 7.8 HIGH
A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution.
CVE-2021-33625 3 Insyde, Netapp, Siemens 34 Insydeh2o, Fas\/aff Bios, Ruggedcom Ape1808 and 31 more 2024-11-21 6.9 MEDIUM 7.5 HIGH
An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.