Vulnerabilities (CVE)

Filtered by vendor Philips Subscribe
Total 107 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2018-10599 1 Philips 36 Avalon Fetal\/maternal Monitors Fm20, Avalon Fetal\/maternal Monitors Fm20 Firmware, Avalon Fetal\/maternal Monitors Fm30 and 33 more 2024-11-21 2.9 LOW 5.3 MEDIUM
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet.
CVE-2018-10597 1 Philips 36 Avalon Fetal\/maternal Monitors Fm20, Avalon Fetal\/maternal Monitors Fm20 Firmware, Avalon Fetal\/maternal Monitors Fm30 and 33 more 2024-11-21 5.4 MEDIUM 8.3 HIGH
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory ("write-what-where") from an attacker-chosen device address within the same subnet.
CVE-2017-9658 1 Philips 2 Intellivue Mx40, Intellivue Mx40 Firmware 2024-11-21 6.1 MEDIUM 6.5 MEDIUM
Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this state, the Philips IntelliVue MX40 Version B.06.18 can either connect to an alternative access point within signal range for association to a central monitoring station, or it can remain in local monitoring mode until the device is reset by hospital staff. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.
CVE-2017-9657 1 Philips 2 Intellivue Mx40, Intellivue Mx40 Firmware 2024-11-21 3.3 LOW 6.5 MEDIUM
Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor, and thus should be operating in local monitoring mode (local audio-on, screen-on), but the MX40 WLAN itself can instead still be operating in telemetry mode (local audio-off, screen-off). If a patient experiences an alarm event and clinical staff expects the MX40 to provide local alarming when it is not available from the local device, a delay of treatment can occur. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.
CVE-2017-9656 1 Philips 1 Dosewise 2024-11-21 6.5 MEDIUM 9.1 CRITICAL
The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevated privileges are first required for an attacker to access the web application backend system files that contain the hard-coded credentials. Successful exploitation may allow a remote attacker to gain access to the database of the DWP application, which contains PHI. CVSS v3 base score: 9.1, CVSS vector string: AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H.
CVE-2017-9654 1 Philips 1 Dosewise 2024-11-21 4.0 MEDIUM 8.8 HIGH
The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N.
CVE-2017-3210 4 Fujitsu, Hp, Philips and 1 more 6 Displayview Click, Displayview Click Suite, Display Assistant and 3 more 2024-11-21 7.2 HIGH 7.8 HIGH
Applications developed using the Portrait Display SDK, versions 2.30 through 2.34, default to insecure configurations which allow arbitrary code execution. A number of applications developed using the Portrait Displays SDK do not use secure permissions when running. These applications run the component pdiservice.exe with NT AUTHORITY/SYSTEM permissions. This component is also read/writable by all Authenticated Users. This allows local authenticated attackers to run arbitrary code with SYSTEM privileges. The following applications have been identified by Portrait Displays as affected: Fujitsu DisplayView Click: Version 6.0 and 6.01. The issue was fixed in Version 6.3. Fujitsu DisplayView Click Suite: Version 5. The issue is addressed by patch in Version 5.9. HP Display Assistant: Version 2.1. The issue was fixed in Version 2.11. HP My Display: Version 2.0. The issue was fixed in Version 2.1. Philips Smart Control Premium: Versions 2.23, 2.25. The issue was fixed in Version 2.26.