CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-23448 | 1 Siemens | 2 Simatic Energy Manager Basic, Simatic Energy Manager Pro | 2024-11-21 | 7.2 HIGH | 7.8 HIGH |
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges. | |||||
CVE-2022-23312 | 1 Siemens | 1 Spectrum Power 4 | 2024-11-21 | 4.3 MEDIUM | 6.1 MEDIUM |
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP9 Security Patch 1). The integrated web application "Online Help" in affected product contains a Cross-Site Scripting (XSS) vulnerability that could be exploited if unsuspecting users are tricked into accessing a malicious link. | |||||
CVE-2022-23102 | 1 Siemens | 1 Sinema Remote Connect Server | 2024-11-21 | 5.8 MEDIUM | 6.1 MEDIUM |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0). Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks. | |||||
CVE-2022-0396 | 4 Fedoraproject, Isc, Netapp and 1 more | 19 Fedora, Bind, H300e and 16 more | 2024-11-21 | 4.3 MEDIUM | 5.3 MEDIUM |
BIND 9.16.11 -> 9.16.26, 9.17.0 -> 9.18.0 and versions 9.16.11-S1 -> 9.16.26-S1 of the BIND Supported Preview Edition. Specifically crafted TCP streams can cause connections to BIND to remain in CLOSE_WAIT status for an indefinite period of time, even after the client has terminated the connection. | |||||
CVE-2022-0235 | 3 Debian, Node-fetch Project, Siemens | 3 Debian Linux, Node-fetch, Sinec Ins | 2024-11-21 | 5.8 MEDIUM | 6.1 MEDIUM |
node-fetch is vulnerable to Exposure of Sensitive Information to an Unauthorized Actor | |||||
CVE-2022-0155 | 2 Follow-redirects Project, Siemens | 2 Follow-redirects, Sinec Ins | 2024-11-21 | 4.3 MEDIUM | 6.5 MEDIUM |
follow-redirects is vulnerable to Exposure of Private Personal Information to an Unauthorized Actor | |||||
CVE-2021-4160 | 4 Debian, Openssl, Oracle and 1 more | 8 Debian Linux, Openssl, Enterprise Manager Ops Center and 5 more | 2024-11-21 | 4.3 MEDIUM | 5.9 MEDIUM |
There is a carry propagation bug in the MIPS32 and MIPS64 squaring procedure. Many EC algorithms are affected, including some of the TLS 1.3 default curves. Impact was not analyzed in detail, because the pre-requisites for attack are considered unlikely and include reusing private keys. Analysis suggests that attacks against RSA and DSA as a result of this defect would be very difficult to perform and are not believed likely. Attacks against DH are considered just feasible (although very difficult) because most of the work necessary to deduce information about a private key may be performed offline. The amount of resources required for such an attack would be significant. However, for an attack on TLS to be meaningful, the server would have to share the DH private key among multiple clients, which is no longer an option since CVE-2016-0701. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0.0. It was addressed in the releases of 1.1.1m and 3.0.1 on the 15th of December 2021. For the 1.0.2 release it is addressed in git commit 6fc1aaaf3 that is available to premium support customers only. It will be made available in 1.0.2zc when it is released. The issue only affects OpenSSL on MIPS platforms. Fixed in OpenSSL 3.0.1 (Affected 3.0.0). Fixed in OpenSSL 1.1.1m (Affected 1.1.1-1.1.1l). Fixed in OpenSSL 1.0.2zc-dev (Affected 1.0.2-1.0.2zb). | |||||
CVE-2021-46699 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.1). Affected application contains a stack based buffer overflow vulnerability while parsing specially crafted BDF files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15061) | |||||
CVE-2021-46304 | 1 Siemens | 8 Cp-8000 Master Module With I\/o -25\/\+70, Cp-8000 Master Module With I\/o -25\/\+70 Firmware, Cp-8000 Master Module With I\/o -40\/\+70 and 5 more | 2024-11-21 | N/A | 7.5 HIGH |
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions), CP-8021 MASTER MODULE (All versions), CP-8022 MASTER MODULE WITH GPRS (All versions). The component allows to activate a web server module which provides unauthenticated access to its web pages. This could allow an attacker to retrieve debug-level information from the component such as internal network topology or connected systems. | |||||
CVE-2021-46162 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.1). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15048) | |||||
CVE-2021-46161 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15302) | |||||
CVE-2021-46160 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15286) | |||||
CVE-2021-46159 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15050) | |||||
CVE-2021-46158 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a stack based buffer overflow vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15085, ZDI-CAN-15289, ZDI-CAN-15602) | |||||
CVE-2021-46157 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a memory corruption vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14757) | |||||
CVE-2021-46156 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14684) | |||||
CVE-2021-46155 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a stack based buffer overflow vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14683, ZDI-CAN-15283, ZDI-CAN-15303, ZDI-CAN-15593) | |||||
CVE-2021-46154 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a stack based buffer overflow vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14646, ZDI-CAN-14679, ZDI-CAN-15084, ZDI-CAN-15304) | |||||
CVE-2021-46153 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a memory corruption vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14645, ZDI-CAN-15305, ZDI-CAN-15589, ZDI-CAN-15599) | |||||
CVE-2021-46152 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a type confusion vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14643, ZDI-CAN-14644, ZDI-CAN-14755, ZDI-CAN-15183) |