Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Total 1901 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-32259 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 6.4 MEDIUM 6.5 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The system images for installation or update of the affected application contain unit test scripts with sensitive information. An attacker could gain information about testing architecture and also tamper with test configuration.
CVE-2022-32258 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains an older feature that allows to import device configurations via a specific endpoint. An attacker could use this vulnerability for information disclosure.
CVE-2022-32257 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 N/A 9.8 CRITICAL
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to resources and potentially lead to code execution.
CVE-2022-32256 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 4.0 MEDIUM 4.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to low privileged users accessing privileged information.
CVE-2022-32255 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 5.0 MEDIUM 5.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to limited information.
CVE-2022-32254 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 5.0 MEDIUM 4.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker.
CVE-2022-32253 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 5.0 MEDIUM 4.9 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). Due to improper input validation, the OpenSSL certificate's password could be printed to a file reachable by an attacker.
CVE-2022-32252 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 9.3 HIGH 6.5 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The application does not perform the integrity check of the update packages. Without validation, an admin user might be tricked to install a malicious package, granting root privileges to an attacker.
CVE-2022-32251 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 7.5 HIGH 8.8 HIGH
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an administrative user.
CVE-2022-32222 2 Nodejs, Siemens 2 Node.js, Sinec Ins 2024-11-21 N/A 5.3 MEDIUM
A cryptographic vulnerability exists on Node.js on linux in versions of 18.x prior to 18.40.0 which allowed a default path for openssl.cnf that might be accessible under some circumstances to a non-admin user instead of /etc/ssl as was the case in versions prior to the upgrade to OpenSSL 3.
CVE-2022-32215 6 Debian, Fedoraproject, Llhttp and 3 more 6 Debian Linux, Fedora, Llhttp and 3 more 2024-11-21 N/A 6.5 MEDIUM
The llhttp parser <v14.20.1, <v16.17.1 and <v18.9.1 in the http module in Node.js does not correctly handle multi-line Transfer-Encoding headers. This can lead to HTTP Request Smuggling (HRS).
CVE-2022-32213 6 Debian, Fedoraproject, Llhttp and 3 more 6 Debian Linux, Fedora, Llhttp and 3 more 2024-11-21 N/A 6.5 MEDIUM
The llhttp parser <v14.20.1, <v16.17.1 and <v18.9.1 in the http module in Node.js does not correctly parse and validate Transfer-Encoding headers and can lead to HTTP Request Smuggling (HRS).
CVE-2022-32212 4 Debian, Fedoraproject, Nodejs and 1 more 4 Debian Linux, Fedora, Node.js and 1 more 2024-11-21 N/A 8.1 HIGH
A OS Command Injection vulnerability exists in Node.js versions <14.20.0, <16.20.0, <18.5.0 due to an insufficient IsAllowedHost check that can easily be bypassed because IsIPAddress does not properly check if an IP address is invalid before making DBS requests allowing rebinding attacks.
CVE-2022-32145 1 Siemens 1 Teamcenter Active Workspace 2024-11-21 4.3 MEDIUM 6.1 MEDIUM
A vulnerability has been identified in Teamcenter Active Workspace V5.2 (All versions < V5.2.9), Teamcenter Active Workspace V6.0 (All versions < V6.0.3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious code by tricking users into accessing a malicious link.
CVE-2022-31810 1 Siemens 1 Sipass Integrated 2024-11-21 N/A 7.5 HIGH
A vulnerability has been identified in SiPass integrated (All versions < V2.90.3.8). Affected server applications improperly check the size of data packets received for the configuration client login, causing a stack-based buffer overflow. This could allow an unauthenticated remote attacker to crash the server application, creating a denial of service condition.
CVE-2022-31808 1 Siemens 4 Sipass Integrated Ac5102 \(acc-g2\), Sipass Integrated Ac5102 \(acc-g2\) Firmware, Sipass Integrated Acc-ap and 1 more 2024-11-21 N/A 7.8 HIGH
A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V2.85.44), SiPass integrated ACC-AP (All versions < V2.85.43). Affected devices improperly sanitize user input on the telnet command line interface. This could allow an authenticated user to escalate privileges by injecting arbitrary commands that are executed with root privileges.
CVE-2022-31765 1 Siemens 372 6ag1206-2bb00-7ac2, 6ag1206-2bb00-7ac2 Firmware, 6ag1206-2bs00-7ac2 and 369 more 2024-11-21 N/A 8.8 HIGH
Affected devices do not properly authorize the change password function of the web interface. This could allow low privileged users to escalate their privileges.
CVE-2022-31619 1 Siemens 1 Teamcenter 2024-11-21 6.5 MEDIUM 8.8 HIGH
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.13), Teamcenter V13.0 (All versions < V13.0.0.9), Teamcenter V13.1 (All versions < V13.1.0.9), Teamcenter V13.2 (All versions < V13.2.0.9), Teamcenter V13.3 (All versions < V13.3.0.3), Teamcenter V14.0 (All versions < V14.0.0.2). Java EE Server Manager HTML Adaptor in Teamcenter consists of default hardcoded credentials. Access to the application allows a user to perform a series of actions that could potentially lead to remote code execution with elevated permissions.
CVE-2022-31465 1 Siemens 1 Xpedition Designer 2024-11-21 4.6 MEDIUM 7.8 HIGH
A vulnerability has been identified in Xpedition Designer VX.2.10 (All versions < VX.2.10 Update 13), Xpedition Designer VX.2.11 (All versions < VX.2.11 Update 11), Xpedition Designer VX.2.12 (All versions < VX.2.12 Update 5), Xpedition Designer VX.2.13 (All versions < VX.2.13 Update 1). The affected application assigns improper access rights to the service executable. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges.
CVE-2022-30938 1 Siemens 6 En100 Ethernet Module, En100 Ethernet Module Dnp3 Ip Firmware, En100 Ethernet Module Iec 104 Firmware and 3 more 2024-11-21 5.0 MEDIUM 7.5 HIGH
A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.40), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint manupulating a specific argument. This could allow an attacker to crash the affected application leading to a denial of service condition