Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Total 1846 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-57583 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda AC18 V15.03.05.19 was discovered to contain a command injection vulnerability via the usbName parameter in the formSetSambaConf function.
CVE-2024-57582 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the startIP parameter in the formSetPPTPServer function.
CVE-2024-57581 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
CVE-2024-57580 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function.
CVE-2024-57579 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the limitSpeedUp parameter in the formSetClientState function.
CVE-2024-57578 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 8.8 HIGH
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the funcpara1 parameter in the formSetCfm function.
CVE-2024-57577 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 5.7 MEDIUM
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
CVE-2024-57575 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
CVE-2024-52789 1 Tenda 2 W30e, W30e Firmware 2026-06-17 N/A 8.0 HIGH
Tenda W30E v2.0 V16.01.0.8 was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root.
CVE-2024-52788 1 Tenda 2 W9, W9 Firmware 2026-06-17 N/A 8.0 HIGH
Tenda W9 v1.0.0.7(4456) was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root.
CVE-2024-52275 1 Tenda 2 Ac6, Ac6 Firmware 2026-06-17 N/A 9.8 CRITICAL
Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (fromWizardHandle modules) allows Overflow Buffers.This issue affects Tenda AC6V2: through 15.03.06.50.
CVE-2024-52274 1 Tenda 2 Ac6, Ac6 Firmware 2026-06-17 N/A 9.8 CRITICAL
Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (setDoubleL2tpConfig->guest_ip_check(overflow arg: mask) modules) allows Overflow Buffers.This issue affects Tenda AC6V2: through 15.03.06.50
CVE-2024-52273 1 Tenda 2 Ac6, Ac6 Firmware 2026-06-17 N/A 9.8 CRITICAL
Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (setDoublePppoeConfig->guest_ip_check(overflow arg: mask) modules) allows Overflow Buffers.This issue affects Tenda AC6V2: through 15.03.06.50
CVE-2024-52272 1 Tenda 2 Ac6, Ac6 Firmware 2026-06-17 N/A 9.8 CRITICAL
Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (fromAdvSetLanip(overflow arg:lanMask) modules) allows Overflow Buffers.This issue affects Tenda AC6V2: through 15.03.06.50
CVE-2024-51409 1 Tenda 2 O3, O3 Firmware 2026-06-17 N/A 6.5 MEDIUM
Buffer Overflow vulnerability in Tenda O3 v.1.0.0.5 allows a remote attacker to cause a denial of service via a network packet in a fixed format to a router running the corresponding version of the firmware.
CVE-2024-51116 1 Tenda 2 Ac6, Ac6 Firmware 2026-06-17 N/A 8.8 HIGH
Tenda AC6 v2.0 V15.03.06.50 was discovered to contain a buffer overflow in the function 'formSetPPTPServer'.
CVE-2024-4497 1 Tenda 2 I21, I21 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4496 1 Tenda 2 I21, I21 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4495 1 Tenda 2 I21, I21 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4494 1 Tenda 2 I21, I21 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.