CVE-2025-53706 2026-03-10 N/A N/A
Rejected reason: ** REJECT ** DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: The CNA or individual who requested this candidate did not associate it with any vulnerability during 2025. Notes: none.
CVE-2025-53608 2026-03-10 N/A 4.8 MEDIUM
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability [CWE-79] vulnerability in Fortinet FortiSandbox 5.0.0 through 5.0.2, FortiSandbox 4.4.0 through 4.4.7, FortiSandbox 4.2 all versions, FortiSandbox 4.0 all versions may allow an authenticated privileged attacker to execute code via crafted requests.
CVE-2025-53335 2026-03-10 N/A 8.1 HIGH
Improper Control of Filename for Include/Require Statement in PHP Program ('PHP Remote File Inclusion') vulnerability in ThemeREX Berger berger allows PHP Local File Inclusion.This issue affects Berger: from n/a through <= 1.1.1.
CVE-2025-49784 2026-03-10 N/A 6.0 MEDIUM
An improper neutralization of special elements used in an sql command ('sql injection') vulnerability in Fortinet FortiAnalyzer 7.6.0 through 7.6.4, FortiAnalyzer 7.4.0 through 7.4.7, FortiAnalyzer 7.2 all versions, FortiAnalyzer 7.0 all versions, FortiAnalyzer 6.4 all versions, FortiAnalyzer-BigData 7.6.0, FortiAnalyzer-BigData 7.4.0 through 7.4.4, FortiAnalyzer-BigData 7.2 all versions, FortiAnalyzer-BigData 7.0 all versions, FortiAnalyzer-BigData 6.4 all versions, FortiAnalyzer-BigData 6.2 all versions may allow an authenticated attacker to execute unauthorized code or commands via specifically crafted requests.
CVE-2025-48840 2026-03-10 N/A 5.3 MEDIUM
An authentication bypass by spoofing vulnerability in Fortinet FortiWeb 7.6.0 through 7.6.3, FortiWeb 7.4.0 through 7.4.8, FortiWeb 7.2 all versions, FortiWeb 7.0 all versions may allow a remote unauthenticated attacker to bypass hostname restrictions via a specially crafted request.
CVE-2025-48418 2026-03-10 N/A 6.7 MEDIUM
A hidden functionality vulnerability in Fortinet FortiAnalyzer 7.6.0 through 7.6.3, FortiAnalyzer 7.4.0 through 7.4.7, FortiAnalyzer 7.2.0 through 7.2.10, FortiAnalyzer 7.0.0 through 7.0.14, FortiAnalyzer 6.4 all versions, FortiAnalyzer Cloud 7.6.2, FortiAnalyzer Cloud 7.4.1 through 7.4.7, FortiAnalyzer Cloud 7.2.1 through 7.2.10, FortiAnalyzer Cloud 7.0.1 through 7.0.14, FortiAnalyzer Cloud 6.4 all versions, FortiManager 7.6.0 through 7.6.3, FortiManager 7.4.0 through 7.4.7, FortiManager 7.2.0 through 7.2.10, FortiManager 7.0.0 through 7.0.14, FortiManager 6.4 all versions, FortiManager Cloud 7.6.2 through 7.6.3, FortiManager Cloud 7.4.1 through 7.4.7, FortiManager Cloud 7.2.1 through 7.2.10, FortiManager Cloud 7.0.1 through 7.0.14, FortiManager Cloud 6.4 all versions may allow a remote authenticated read-only admin with CLI access to escalate their privilege via use of a hidden command.
CVE-2025-41712 2026-03-10 N/A 6.5 MEDIUM
An unauthenticated remote attacker who tricks a user to upload a manipulated HTML file can get access to sensitive information on the device. This is a result of incorrect permission assignment for the web server.
CVE-2025-41711 2026-03-10 N/A 5.3 MEDIUM
An unauthenticated remote attacker can use firmware images to extract password hashes and brute force plaintext passwords of accounts with limited access.
CVE-2025-41710 2026-03-10 N/A 6.5 MEDIUM
An unauthenticated remote attacker may use hardcodes credentials to get access to the previously activated FTP Server with limited read and write privileges.
CVE-2025-41709 2026-03-10 N/A 9.8 CRITICAL
[PROBLEMTYPE] in [COMPONENT] in [VENDOR] [PRODUCT] [VERSION] on [PLATFORMS] allows [ATTACKER] to [IMPACT] via [VECTOR]
CVE-2025-40943 2026-03-10 N/A 9.6 CRITICAL
Affected devices do not properly sanitize contents of trace files. This could allow an attacker to inject code through social engineering a legitimate user to import a specially crafted trace file
CVE-2025-40801 2026-03-10 N/A 8.1 HIGH
A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), JT Bi-Directional Translator for STEP (All versions), NX V2412 (All versions < V2412.8900 with Cloud Entitlement (bundled as NX X)), NX V2506 (All versions < V2506.6000 with Cloud Entitlement (bundled as NX X)), Simcenter 3D (All versions < V2506.6000 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Femap (All versions < V2506.0002 with Cloud Entitlement (bundled as Simcenter X Mechanical)), Simcenter Studio (All versions < V2506.0001), Simcenter System Architect (All versions < V2506.0001), Tecnomatix Plant Simulation (All versions < V2504.0007). The SALT SDK is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.
CVE-2025-40800 2026-03-10 N/A 7.4 HIGH
A vulnerability has been identified in COMOS V10.6 (All versions < V10.6.1), COMOS V10.6 (All versions < V10.6.1), NX V2412 (All versions < V2412.8700), NX V2506 (All versions < V2506.6000), Simcenter 3D (All versions < V2506.6000), Simcenter Femap (All versions < V2506.0002), Solid Edge SE2025 (All versions < V225.0 Update 10), Solid Edge SE2026 (All versions < V226.0 Update 1). The IAM client in affected products is missing server certificate validation while establishing TLS connections to the authorization server. This could allow an attacker to perform a man-in-the-middle attack.
CVE-2025-40594 1 Siemens 6 Sinamics G220, Sinamics G220 Firmware, Sinamics S200 and 3 more 2026-03-10 N/A 6.3 MEDIUM
A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions < V6.4 HF7), SINAMICS S210 V6.4 (All versions < V6.4 HF2). The affected devices allow a factory reset to be executed without the required privileges due to improper privilege management as well as manipulation of configuration data because of leaked privileges of previous sessions. This could allow an unauthorized attacker to escalate their privileges.
CVE-2025-27769 2026-03-10 N/A 2.6 LOW
A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable.
CVE-2025-13957 2026-03-10 N/A N/A
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default.
CVE-2025-13902 2026-03-10 N/A N/A
CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload.
CVE-2025-13901 2026-03-10 N/A N/A
CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels.
CVE-2025-11739 2026-03-10 N/A N/A
CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.
CVE-2024-47565 1 Siemens 1 Sinec Security Monitor 2026-03-10 N/A 4.3 MEDIUM
A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly validate that user input complies with a list of allowed values. This could allow an authenticated remote attacker to compromise the integrity of the configuration of the affected application.