Filtered by vendor Siemens
Subscribe
Total
2107 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2022-38371 | 1 Siemens | 39 Apogee Modular Building Controller, Apogee Modular Building Controller Firmware, Apogee Modular Equiment Controller and 36 more | 2025-04-08 | N/A | 7.5 HIGH |
| A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), Desigo PXC00-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC00-U (All versions >= V2.3 < V6.30.37), Desigo PXC001-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC100-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC12-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC128-U (All versions >= V2.3 < V6.30.37), Desigo PXC200-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC22-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC22.1-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC36.1-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC50-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC64-U (All versions >= V2.3 < V6.30.37), Desigo PXM20-E (All versions >= V2.3 < V6.30.37), Nucleus NET for Nucleus PLUS V1 (All versions < V5.2a), Nucleus NET for Nucleus PLUS V2 (All versions < V5.4), Nucleus ReadyStart V3 V2012 (All versions < V2012.08.1), Nucleus ReadyStart V3 V2017 (All versions < V2017.02.4), Nucleus Source Code (All versions including affected FTP server), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The FTP server does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to generate a denial of service condition on devices that incorporate a vulnerable version of the FTP server. | |||||
| CVE-2000-0964 | 1 Siemens | 1 Hinet Lp | 2025-04-03 | 10.0 HIGH | N/A |
| Buffer overflow in the web administration service for the HiNet LP5100 IP-phone allows remote attackers to cause a denial of service and possibly execute arbitrary commands via a long GET request. | |||||
| CVE-2001-0411 | 1 Siemens | 1 Reliant Unix | 2025-04-03 | 5.0 MEDIUM | N/A |
| Reliant Unix 5.44 and earlier allows remote attackers to cause a denial of service via an ICMP port unreachable packet, which causes Reliant to drop all connections to the source address of the packet. | |||||
| CVE-2002-0122 | 1 Siemens | 1 3568i Wap | 2025-04-03 | 5.0 MEDIUM | N/A |
| Siemens 3568i WAP mobile phones allows remote attackers to cause a denial of service (crash) via an SMS message containing unusual characters. | |||||
| CVE-2006-3907 | 1 Siemens | 1 Speedstream Wireless Router | 2025-04-03 | 5.0 MEDIUM | N/A |
| Siemens SpeedStream 2624 allows remote attackers to cause a denial of service (device hang) by sending a crafted packet to the web administrative interface. | |||||
| CVE-2001-0384 | 1 Siemens | 1 Reliant Unix | 2025-04-03 | 2.1 LOW | N/A |
| ppd in Reliant Sinix allows local users to corrupt arbitrary files via a symlink attack in the /tmp/ppd.trace file. | |||||
| CVE-2003-0190 | 3 Openbsd, Openpkg, Siemens | 6 Openssh, Openpkg, Scalance X204rna and 3 more | 2025-04-03 | 5.0 MEDIUM | N/A |
| OpenSSH-portable (OpenSSH) 3.6.1p1 and earlier with PAM support enabled immediately sends an error message when a user does not exist, which allows remote attackers to determine valid usernames via a timing attack. | |||||
| CVE-2002-1484 | 1 Siemens | 1 Db4web | 2025-04-03 | 7.5 HIGH | 9.8 CRITICAL |
| DB4Web server, when configured to use verbose debug messages, allows remote attackers to use DB4Web as a proxy and attempt TCP connections to other systems (port scan) via a request for a URL that specifies the target IP address and port, which produces a connection status in the resulting error message. | |||||
| CVE-2004-2626 | 1 Siemens | 1 S55 | 2025-04-03 | 3.7 LOW | N/A |
| GUI overlay vulnerability in the Java API in Siemens S55 cellular phones allows remote attackers to send unauthorized SMS messages by overlaying a confirmation message with a malicious message. | |||||
| CVE-1999-0017 | 9 Caldera, Freebsd, Gnu and 6 more | 11 Openlinux, Freebsd, Inet and 8 more | 2025-04-03 | 7.5 HIGH | N/A |
| FTP servers can allow an attacker to connect to arbitrary ports on machines other than the FTP client, aka FTP bounce. | |||||
| CVE-2003-1464 | 1 Siemens | 2 M45, S45 | 2025-04-03 | 7.8 HIGH | N/A |
| Buffer overflow in Siemens 45 series mobile phones allows remote attackers to cause a denial of service (disconnect and unavailable inbox) via a Short Message Service (SMS) message with a long image name. | |||||
| CVE-2005-2424 | 1 Siemens | 1 Santis 50 | 2025-04-03 | 7.5 HIGH | N/A |
| The management interface for Siemens SANTIS 50 running firmware 4.2.8.0, and possibly other products including Ericsson HN294dp and Dynalink RTA300W, allows remote attackers to access the Telnet port without authentication via certain packets to the web interface that cause the interface to freeze. | |||||
| CVE-2006-3344 | 1 Siemens | 1 Speedstream Wireless Router | 2025-04-03 | 7.5 HIGH | N/A |
| Siemens Speedstream Wireless Router 2624 allows local users to bypass authentication and access protected files by using the Universal Plug and Play UPnP/1.0 component. | |||||
| CVE-2020-8745 | 2 Intel, Siemens | 43 Converged Security And Manageability Engine, Trusted Execution Technology, Simatic Drive Controller and 40 more | 2025-03-28 | 4.6 MEDIUM | 6.8 MEDIUM |
| Insufficient control flow management in subsystem for Intel(R) CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , Intel(R) TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physical access. | |||||
| CVE-2021-25664 | 1 Siemens | 5 Capital Vstar, Nucleus Net, Nucleus Readystart V3 and 2 more | 2025-03-11 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes the Hop-by-Hop extension header in IPv6 packets and its options lacks any checks against the length field of the header, allowing attackers to put the function into an infinite loop by supplying arbitrary length values. | |||||
| CVE-2021-25663 | 1 Siemens | 4 Capital Vstar, Nucleus Net, Nucleus Readystart and 1 more | 2025-03-11 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes IPv6 headers does not check the lengths of extension header options, allowing attackers to put this function into an infinite loop with crafted length values. | |||||
| CVE-2024-54094 | 1 Siemens | 1 Solid Edge Se2024 | 2025-03-04 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 5). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2024-54095 | 1 Siemens | 1 Solid Edge Se2024 | 2025-03-04 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 10). The affected application is vulnerable to integer underflow vulnerability which can be triggered while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2023-29053 | 1 Siemens | 2 Jt Open Toolkit, Jt Utilities | 2025-02-26 | N/A | 7.8 HIGH |
| A vulnerability has been identified in JT Open (All versions < V11.3.2.0), JT Utilities (All versions < V13.3.0.0). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2024-50572 | 1 Siemens | 52 Ruggedcom Rm1224 Lte\(4g\) Eu, Ruggedcom Rm1224 Lte\(4g\) Eu Firmware, Ruggedcom Rm1224 Lte\(4g\) Nam and 49 more | 2025-02-11 | N/A | 7.2 HIGH |
| A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. | |||||
