Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Filtered by product Ac9
Total 82 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-37717 1 Tenda 14 Ac10, Ac10 Firmware, Ac1206 and 11 more 2024-11-21 N/A 9.8 CRITICAL
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.
CVE-2023-37716 1 Tenda 14 Ac10, Ac10 Firmware, Ac1206 and 11 more 2024-11-21 N/A 9.8 CRITICAL
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
CVE-2022-36571 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 N/A 7.2 HIGH
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the mask parameter at /goform/WanParameterSetting.
CVE-2022-36570 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 N/A 7.2 HIGH
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the time parameter at /goform/SetLEDCfg.
CVE-2022-36569 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 N/A 8.8 HIGH
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg.
CVE-2022-36568 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 N/A 8.8 HIGH
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the list parameter at /goform/setPptpUserList.
CVE-2022-36273 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC9 V15.03.2.21_cn is vulnerable to command injection via goform/SetSysTimeCfg.
CVE-2022-28560 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload
CVE-2022-27022 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
There is a stack overflow vulnerability in the SetSysTimeCfg() function in the httpd service of Tenda AC9 V15.03.2.21_cn. The attacker can obtain a stable root shell through a constructed payload.
CVE-2022-27016 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
There is a stack overflow vulnerability in the SetStaticRouteCfg() function in the httpd service of Tenda AC9 15.03.2.21_cn.
CVE-2022-26278 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
Tenda AC9 v15.03.2.21_cn was discovered to contain a stack overflow via the time parameter in the PowerSaveSet function.
CVE-2022-25441 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the vlanid parameter in the SetIPTVCfg function.
CVE-2022-25440 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the ntpserver parameter in the SetSysTimeCfg function.
CVE-2022-25439 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetIpMacBind function.
CVE-2022-25438 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
Tenda AC9 v15.03.2.21 was discovered to contain a remote command execution (RCE) vulnerability via the SetIPTVCfg function.
CVE-2022-25437 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetVirtualServerCfg function.
CVE-2022-25435 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetStaticRoutecfg function.
CVE-2022-25434 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the firewallen parameter in the SetFirewallCfg function.
CVE-2022-25433 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the urls parameter in the saveparentcontrolinfo function.
CVE-2022-25431 1 Tenda 2 Ac9, Ac9 Firmware 2024-11-21 10.0 HIGH 9.8 CRITICAL
Tenda AC9 v15.03.2.21 was discovered to contain multiple stack overflows via the NPTR, V12, V10 and V11 parameter in the Formsetqosband function.