Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Filtered by product Ac18
Total 76 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-2560 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-22 5.0 MEDIUM 4.3 MEDIUM
A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2489 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-14 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2490 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-14 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2488 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-14 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2487 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-14 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2485 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-14 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2486 1 Tenda 2 Ac18, Ac18 Firmware 2025-01-14 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability.
CVE-2024-2854 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 6.5 MEDIUM 6.3 MEDIUM
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-38823 1 Tenda 8 Ac18, Ac18 Firmware, Ac19 and 5 more 2024-11-21 N/A 9.8 CRITICAL
Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd.
CVE-2022-43260 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC18 V15.03.05.19(6318) was discovered to contain a stack overflow via the time parameter in the fromSetSysTime function.
CVE-2022-40861 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 N/A 7.2 HIGH
Tenda AC18 router V15.03.05.19 contains a stack overflow vulnerability in the formSetQosBand->FUN_0007db78 function with the request /goform/SetNetControlList/
CVE-2022-40854 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC18 router contained a stack overflow vulnerability in /goform/fast_setting_wifi_set
CVE-2022-38314 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the urls parameter at /goform/saveParentControlInfo.
CVE-2022-38313 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/saveParentControlInfo.
CVE-2022-38312 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetIpMacBind.
CVE-2022-38311 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the time parameter at /goform/PowerSaveSet.
CVE-2022-38310 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetStaticRouteCfg.
CVE-2022-38309 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda AC18 router v15.03.05.19 and v15.03.05.05 was discovered to contain a stack overflow via the list parameter at /goform/SetVirtualServerCfg.
CVE-2022-35201 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 N/A 9.8 CRITICAL
Tenda-AC18 V15.03.05.05 was discovered to contain a remote command execution (RCE) vulnerability.
CVE-2022-30477 1 Tenda 2 Ac18, Ac18 Firmware 2024-11-21 7.5 HIGH 9.8 CRITICAL
Tenda AC Series Router AC18_V15.03.05.19(6318) was discovered to contain a stack-based buffer overflow in the httpd module when handling /goform/SetClientState request.