Filtered by vendor Tenda
Subscribe
Total
1346 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-32313 | 1 Tenda | 2 Fh1205, Fh1205 Firmware | 2025-03-17 | N/A | 6.5 MEDIUM |
Tenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the adslPwd parameter of the formWanParameterSetting function. | |||||
CVE-2024-32307 | 1 Tenda | 2 Fh1205, Fh1205 Firmware | 2025-03-17 | N/A | 7.4 HIGH |
Tenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function. | |||||
CVE-2024-57704 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-03-17 | N/A | 8.8 HIGH |
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. | |||||
CVE-2024-46652 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability in the fromAdvSetMacMtuWan function. | |||||
CVE-2024-57703 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. | |||||
CVE-2024-32310 | 1 Tenda | 2 F1203, F1203 Firmware | 2025-03-17 | N/A | 8.0 HIGH |
Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the PPW parameter of the fromWizardHandle function. | |||||
CVE-2024-32312 | 1 Tenda | 2 F1203, F1203 Firmware | 2025-03-17 | N/A | 5.7 MEDIUM |
Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function. | |||||
CVE-2024-32283 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2025-03-17 | N/A | 7.3 HIGH |
Tenda FH1203 V2.0.1.6 firmware has a command injection vulnerablility in formexeCommand function via the cmdinput parameter. | |||||
CVE-2024-32311 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2025-03-17 | N/A | 6.5 MEDIUM |
Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function. | |||||
CVE-2024-32299 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2025-03-17 | N/A | 8.8 HIGH |
Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function. | |||||
CVE-2024-57578 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-17 | N/A | 8.8 HIGH |
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the funcpara1 parameter in the formSetCfm function. | |||||
CVE-2024-57577 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-17 | N/A | 5.7 MEDIUM |
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. | |||||
CVE-2024-34974 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-03-17 | N/A | 8.2 HIGH |
Tenda AC18 v15.03.05.19 is vulnerable to Buffer Overflow in the formSetPPTPServer function via the endIp parameter. | |||||
CVE-2024-32314 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-03-17 | N/A | 3.8 LOW |
Tenda AC500 V2.0.1.9(1307) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter. | |||||
CVE-2024-32316 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-03-17 | N/A | 6.5 MEDIUM |
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function. | |||||
CVE-2024-32318 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo function. | |||||
CVE-2024-32320 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-03-17 | N/A | 5.9 MEDIUM |
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function. | |||||
CVE-2024-33215 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | N/A | 9.8 CRITICAL |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/addressNat. | |||||
CVE-2024-33214 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | N/A | 7.5 HIGH |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter in ip/goform/RouteStatic. | |||||
CVE-2024-33212 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | N/A | 8.8 HIGH |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter in ip/goform/setcfm. |