Filtered by vendor Tenda
Subscribe
Total
1168 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-2986 | 1 Tenda | 2 Fh1202, Fh1202 Firmware | 2025-01-14 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258155. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2987 | 1 Tenda | 2 Fh1202, Fh1202 Firmware | 2025-01-14 | 9.0 HIGH | 8.8 HIGH |
A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258156. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2489 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-14 | 9.0 HIGH | 8.8 HIGH |
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2490 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-14 | 9.0 HIGH | 8.8 HIGH |
A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256897 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2488 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-14 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2487 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-14 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2485 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-14 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-2486 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-01-14 | 9.0 HIGH | 8.8 HIGH |
A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability. | |||||
CVE-2023-33675 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-08 | N/A | 9.8 CRITICAL |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function. | |||||
CVE-2023-33673 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-08 | N/A | 9.8 CRITICAL |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function. | |||||
CVE-2023-33672 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-08 | N/A | 7.5 HIGH |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function. | |||||
CVE-2023-33671 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-08 | N/A | 9.8 CRITICAL |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function. | |||||
CVE-2023-33670 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-08 | N/A | 9.8 CRITICAL |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub_4a79ec function. | |||||
CVE-2023-33669 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-01-08 | N/A | 9.8 CRITICAL |
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub_44db3c function. | |||||
CVE-2023-33530 | 1 Tenda | 2 G103, G103 Firmware | 2025-01-08 | N/A | 8.8 HIGH |
There is a command injection vulnerability in the Tenda G103 Gigabit GPON Terminal with firmware version V1.0.0.5. If an attacker gains web management privileges, they can inject commands gaining shell privileges. | |||||
CVE-2023-34568 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | N/A | 6.7 MEDIUM |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet. | |||||
CVE-2023-34566 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | N/A | 9.8 CRITICAL |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo. | |||||
CVE-2023-34571 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | N/A | 6.7 MEDIUM |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter shareSpeed at /goform/WifiGuestSet. | |||||
CVE-2023-34570 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | N/A | 6.7 MEDIUM |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter devName at /goform/SetOnlineDevName. | |||||
CVE-2023-34569 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | N/A | 6.7 MEDIUM |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList. |