Filtered by vendor Tenda
Subscribe
Total
1846 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2025-5763 | 1 Tenda | 2 Cp3, Cp3 Firmware | 2026-06-17 | 5.8 MEDIUM | 4.7 MEDIUM |
| A vulnerability has been found in Tenda CP3 11.10.00.2311090948 and classified as critical. Affected by this vulnerability is the function sub_F3C8C of the file apollo. The manipulation leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-5685 | 1 Tenda | 2 Ch22, Ch22 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability, which was classified as critical, was found in Tenda CH22 1.0.0.1. This affects the function formNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-5629 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability, which was classified as critical, was found in Tenda AC10 up to 15.03.06.47. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg of the component HTTP Handler. The manipulation of the argument startIp/endIp leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-5619 | 1 Tenda | 2 Ch22, Ch22 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability, which was classified as critical, has been found in Tenda CH22 1.0.0.1. This issue affects the function formaddUserName of the file /goform/addUserName. The manipulation of the argument Password leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-5609 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-5608 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formsetreboottimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-5607 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-5606 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2026-06-17 | 6.5 MEDIUM | 6.3 MEDIUM |
| A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetIptv of the file /goform/SetIPTVCfg. The manipulation of the argument list leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-5527 | 1 Tenda | 2 Rx3, Rx3 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-5080 | 1 Tenda | 2 Fh451, Fh451 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function webExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-57639 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2026-06-17 | N/A | 6.5 MEDIUM |
| OS Command injection vulnerability in Tenda AC9 1.0 was discovered to contain a command injection vulnerability via the usb.samba.guest.user parameter in the formSetSambaConf function of the httpd file. | |||||
| CVE-2025-57638 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| Buffer overflow vulnerability in Tenda AC9 1.0 via the user supplied sys.vendor configuration value. | |||||
| CVE-2025-57528 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2026-06-17 | N/A | 7.7 HIGH |
| An issue was discovered in Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01 allowing attackers to cause a denial of service via the funcname, funcpara1, funcpara2 parameters to the formSetCfm function (uri path: SetCfm). | |||||
| CVE-2025-57296 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2026-06-17 | N/A | 6.5 MEDIUM |
| Tenda AC6 router firmware 15.03.05.19 contains a command injection vulnerability in the formSetIptv function, which processes requests to the /goform/SetIPTVCfg web interface. When handling the list and vlanId parameters, the sub_ADBC0 helper function concatenates these user-supplied values into nvram set system commands using doSystemCmd, without validating or sanitizing special characters (e.g., ;, ", #). An unauthenticated or authenticated attacker can exploit this by submitting a crafted POST request, leading to arbitrary system command execution on the affected device. | |||||
| CVE-2025-57220 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2026-06-17 | N/A | 5.3 MEDIUM |
| An input validation flaw in the 'ate' service of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 to escalate privileges to root via a crafted UDP packet. | |||||
| CVE-2025-57219 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2026-06-17 | N/A | 5.3 MEDIUM |
| Incorrect access control in the endpoint /goform/ate of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 allows attackers to escalate privileges or access sensitive components via a crafted request. | |||||
| CVE-2025-57218 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2026-06-17 | N/A | 5.3 MEDIUM |
| Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the security_5g parameter in the function sub_46284C. | |||||
| CVE-2025-57217 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2026-06-17 | N/A | 5.3 MEDIUM |
| Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the Password parameter in the function R7WebsSecurityHandler. | |||||
| CVE-2025-57215 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| Tenda AC10 v4.0 firmware v16.03.10.20 was discovered to contain a stack overflow via the function get_parentControl_list_Info. | |||||
| CVE-2025-57087 | 1 Tenda | 2 W30e, W30e Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the countryCode parameter in the werlessAdvancedSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request. | |||||
