Vulnerabilities (CVE)

Filtered by vendor Tendacn Subscribe
Total 146 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-42949 1 Tendacn 2 Fh1201, Fh1201 Firmware 2026-06-17 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the qos parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-42945 1 Tendacn 2 Fh1201, Fh1201 Firmware 2026-06-17 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the fromAddressNat function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-42942 1 Tendacn 2 Fh1201, Fh1201 Firmware 2026-06-17 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 (408) was discovered to contain a stack overflow via the page parameter in the frmL7ImForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
CVE-2024-41473 1 Tendacn 2 Fh1201, Fh1201 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda FH1201 v1.2.0.14 was discovered to contain a command injection vulnerability via the mac parameter at ip/goform/WriteFacMac
CVE-2024-41468 1 Tendacn 2 Fh1201, Fh1201 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda FH1201 v1.2.0.14 was discovered to contain a command injection vulnerability via the cmdinput parameter at /goform/exeCommand
CVE-2024-41466 1 Tendacn 2 Fh1201, Fh1201 Firmware 2026-06-17 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/NatStaticSetting.
CVE-2024-41465 1 Tendacn 2 Fh1201, Fh1201 Firmware 2026-06-17 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter at ip/goform/setcfm.
CVE-2024-41464 1 Tendacn 2 Fh1201, Fh1201 Firmware 2026-06-17 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/RouteStatic
CVE-2024-41463 1 Tendacn 2 Fh1201, Fh1201 Firmware 2026-06-17 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter at ip/goform/addressNat.
CVE-2024-41462 1 Tendacn 2 Fh1201, Fh1201 Firmware 2026-06-17 N/A 7.5 HIGH
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/DhcpListClient.
CVE-2024-41461 1 Tendacn 2 Fh1201, Fh1201 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the list1 parameter at ip/goform/DhcpListClient.
CVE-2024-41460 1 Tendacn 2 Fh1201, Fh1201 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter at ip/goform/RouteStatic.
CVE-2024-41459 1 Tendacn 2 Fh1201, Fh1201 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda FH1201 v1.2.0.14 was discovered to contain a stack-based buffer overflow vulnerability via the PPPOEPassword parameter at ip/goform/QuickIndex.
CVE-2024-35338 1 Tendacn 2 I29, I29 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda i29V1.0 V1.0.0.5 was discovered to contain a hardcoded password for root.
CVE-2024-33182 1 Tendacn 2 Ac18, Ac18 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/addWifiMacFilter.
CVE-2024-33180 1 Tendacn 2 Ac18, Ac18 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId parameter at ip/goform/saveParentControlInfo.
CVE-2024-24488 1 Tendacn 2 Cp3, Cp3 Firmware 2026-06-17 N/A 5.5 MEDIUM
An issue in Shenzen Tenda Technology CP3V2.0 V11.10.00.2311090948 allows a local attacker to obtain sensitive information via the password component.
CVE-2024-0932 1 Tendacn 2 Ac10u, Ac10u Firmware 2026-06-17 5.8 MEDIUM 4.7 MEDIUM
A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This issue affects the function setSmartPowerManagement. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-252137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0931 1 Tendacn 2 Ac10u, Ac10u Firmware 2026-06-17 5.8 MEDIUM 4.7 MEDIUM
A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. This vulnerability affects the function saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-0930 1 Tendacn 2 Ac10u, Ac10u Firmware 2026-06-17 5.8 MEDIUM 4.7 MEDIUM
A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.