Vulnerabilities (CVE)

Filtered by vendor Cisco Subscribe
Total 6250 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-1457 1 Cisco 1 Secure Firewall Management Center 2024-11-26 3.5 LOW 4.8 MEDIUM
Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information.
CVE-2019-1982 1 Cisco 3 Firepower Services Software For Asa, Firepower Threat Defense, Secure Firewall Management Center 2024-11-26 5.0 MEDIUM 5.3 MEDIUM
A vulnerability in the HTTP traffic filtering component of Cisco Firepower Threat Defense Software, Cisco FirePOWER Services Software for ASA, and Cisco Firepower Management Center Software could allow an unauthenticated, remote attacker to bypass filtering protections. The vulnerability is due to improper handling of HTTP requests, including those communicated over a secure HTTPS connection, that contain maliciously crafted headers. An attacker could exploit this vulnerability by sending malicious requests to an affected device. An exploit could allow the attacker to bypass filtering and deliver malicious requests to protected systems, allowing attackers to deliver malicious content that would otherwise be blocked.
CVE-2020-3499 1 Cisco 1 Secure Firewall Management Center 2024-11-26 5.0 MEDIUM 8.6 HIGH
A vulnerability in the licensing service of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition.The vulnerability is due to improper handling of system resource values by the affected system. An attacker could exploit this vulnerability by sending malicious requests to the targeted system. A successful exploit could allow the attacker to cause the affected system to become unresponsive, resulting in a DoS condition and preventing the management of dependent devices.
CVE-2020-3550 1 Cisco 2 Firepower Threat Defense, Secure Firewall Management Center 2024-11-26 5.5 MEDIUM 8.1 HIGH
A vulnerability in the sfmgr daemon of Cisco Firepower Management Center (FMC) Software and Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, remote attacker to perform directory traversal and access directories outside the restricted path. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by using a relative path in specific sfmgr commands. An exploit could allow the attacker to read or write arbitrary files on an sftunnel-connected peer device.
CVE-2022-20925 1 Cisco 1 Secure Firewall Management Center 2024-11-26 N/A 6.3 MEDIUM
A vulnerability in the web management interface of the Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system. The vulnerability is due to insufficient validation of user-supplied parameters for certain API endpoints. An attacker could exploit this vulnerability by sending crafted input to an affected API endpoint. A successful exploit could allow an attacker to execute arbitrary commands on the device with low system privileges. To successfully exploit this vulnerability, an attacker would need valid credentials for a user with Device permissions: by default, only Administrators, Security Approvers and Network Admins user accounts have these permissions.
CVE-2019-12690 1 Cisco 1 Secure Firewall Management Center 2024-11-26 9.0 HIGH 7.2 HIGH
A vulnerability in the web UI of the Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to inject arbitrary commands that are executed with the privileges of the root user of the underlying operating system. The vulnerability is due to insufficient validation of user-supplied input to the web UI. An attacker could exploit this vulnerability by submitting crafted input in the web UI. A successful exploit could allow an attacker to execute arbitrary commands on the device with full root privileges.
CVE-2022-20836 1 Cisco 1 Secure Firewall Management Center 2024-11-26 N/A 4.8 MEDIUM
Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface of an affected device. These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information. In some cases, it is also possible to cause a temporary availability impact to portions of the FMC Dashboard.
CVE-2019-12682 1 Cisco 1 Secure Firewall Management Center 2024-11-26 9.0 HIGH 8.8 HIGH
Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary SQL injections on an affected device. These vulnerabilities exist due to improper input validation. An attacker could exploit these vulnerabilities by sending crafted SQL queries to an affected device. A successful exploit could allow the attacker to view information that they are not authorized to view, make changes to the system that they are not authorized to make, and execute commands within the underlying operating system that may affect the availability of the device.
CVE-2019-1699 1 Cisco 1 Secure Firewall Management Center 2024-11-26 7.2 HIGH 6.7 MEDIUM
A vulnerability in the CLI of Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, local attacker to perform a command injection attack. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by injecting commands into arguments for a specific command. A successful exploit could allow the attacker to execute commands with root privileges.
CVE-2019-1696 1 Cisco 2 Firepower Threat Defense, Secure Firewall Management Center 2024-11-26 3.3 LOW 7.5 HIGH
Multiple vulnerabilities in the Server Message Block (SMB) Protocol preprocessor detection engine for Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, adjacent or remote attacker to cause a denial of service (DoS) condition. For more information about these vulnerabilities, see the Details section of this advisory.
CVE-2019-1642 1 Cisco 1 Secure Firewall Management Center 2024-11-26 4.3 MEDIUM 6.1 MEDIUM
A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) software could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the web-based management interface of the affected software. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of the affected software. An attacker could exploit this vulnerability by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.
CVE-2019-12689 1 Cisco 1 Secure Firewall Management Center 2024-11-26 9.0 HIGH 8.8 HIGH
A vulnerability in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary code on the underlying operating system of an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending malicious commands to the web-based management interface of an affected device. A successful exploit could allow the attacker to execute arbitrary code on the underlying operating system of the affected device.
CVE-2022-20905 1 Cisco 1 Secure Firewall Management Center 2024-11-26 N/A 4.8 MEDIUM
Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface of an affected device. These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information. In some cases, it is also possible to cause a temporary availability impact to portions of the FMC Dashboard.
CVE-2019-12681 1 Cisco 1 Secure Firewall Management Center 2024-11-26 9.0 HIGH 8.8 HIGH
Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary SQL injections on an affected device. These vulnerabilities exist due to improper input validation. An attacker could exploit these vulnerabilities by sending crafted SQL queries to an affected device. A successful exploit could allow the attacker to view information that they are not authorized to view, make changes to the system that they are not authorized to make, and execute commands within the underlying operating system that may affect the availability of the device.
CVE-2021-1126 1 Cisco 1 Secure Firewall Management Center 2024-11-26 2.1 LOW 5.5 MEDIUM
A vulnerability in the storage of proxy server credentials of Cisco Firepower Management Center (FMC) could allow an authenticated, local attacker to view credentials for a configured proxy server. The vulnerability is due to clear-text storage and weak permissions of related configuration files. An attacker could exploit this vulnerability by accessing the CLI of the affected software and viewing the contents of the affected files. A successful exploit could allow the attacker to view the credentials that are used to access the proxy server.
CVE-2019-1931 1 Cisco 1 Secure Firewall Management Center 2024-11-26 4.3 MEDIUM 6.1 MEDIUM
Multiple vulnerabilities in the RSS dashboard in the web-based management interface of Cisco Firepower Management Center (FMC) could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the web-based management interface of an affected device. The vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface of the affected device. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.
CVE-2022-20629 1 Cisco 1 Secure Firewall Management Center 2024-11-26 3.5 LOW 5.4 MEDIUM
Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information.
CVE-2023-20206 1 Cisco 1 Secure Firewall Management Center 2024-11-26 N/A 6.1 MEDIUM
Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface of an affected device. These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by inserting crafted input into various data fields in an affected interface. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface, or access sensitive, browser-based information. In some cases, it is also possible to cause a temporary availability impact to portions of the FMC Dashboard.
CVE-2021-1238 1 Cisco 1 Secure Firewall Management Center 2024-11-26 3.5 LOW 4.8 MEDIUM
Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface of an affected system. The vulnerabilities exist because the web-based management interface does not properly validate user-supplied input. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.
CVE-2020-3410 1 Cisco 1 Secure Firewall Management Center 2024-11-26 6.8 MEDIUM 8.1 HIGH
A vulnerability in the Common Access Card (CAC) authentication feature of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to bypass authentication and access the FMC system. The attacker must have a valid CAC to initiate the access attempt. The vulnerability is due to incorrect session invalidation during CAC authentication. An attacker could exploit this vulnerability by performing a CAC-based authentication attempt to an affected system. A successful exploit could allow the attacker to access an affected system with the privileges of a CAC-authenticated user who is currently logged in.