Total
311877 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-8554 | 1 Oretnom23 | 1 Clinic\'s Patient Management System | 2024-09-10 | 4.0 MEDIUM | 5.4 MEDIUM |
A vulnerability was found in SourceCodester Clinics Patient Management System 2.0 and classified as problematic. This issue affects some unknown processing of the file /users.php. The manipulation of the argument message leads to cross site scripting. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2024-41729 | 2024-09-10 | N/A | 4.3 MEDIUM | ||
Due to missing authorization checks, SAP BEx Analyzer allows an authenticated attacker to access information over the network which is otherwise restricted. On successful exploitation the attacker can enumerate information causing a limited impact on confidentiality of the application. | |||||
CVE-2024-42500 | 2024-09-10 | N/A | 9.3 CRITICAL | ||
HPE has identified a denial of service vulnerability in HPE HP-UX System's Network File System (NFSv4) services. | |||||
CVE-2024-45284 | 2024-09-10 | N/A | 2.4 LOW | ||
An authenticated attacker with high privilege can use functions of SLCM transactions to which access should be restricted. This may result in an escalation of privileges causing low impact on integrity of the application. | |||||
CVE-2024-45032 | 2024-09-10 | N/A | 10.0 CRITICAL | ||
A vulnerability has been identified in Industrial Edge Management Pro (All versions < V1.9.5), Industrial Edge Management Virtual (All versions < V2.3.1-1). Affected components do not properly validate the device tokens. This could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system. | |||||
CVE-2024-43781 | 2024-09-10 | N/A | 5.5 MEDIUM | ||
A vulnerability has been identified in SINUMERIK 828D V4 (All versions < V4.95 SP3), SINUMERIK 840D sl V4 (All versions < V4.95 SP3 in connection with using Create MyConfig (CMC) <= V4.8 SP1 HF6), SINUMERIK ONE (All versions < V6.23 in connection with using Create MyConfig (CMC) <= V6.6), SINUMERIK ONE (All versions < V6.15 SP4 in connection with using Create MyConfig (CMC) <= V6.6). Affected systems, that have been provisioned with Create MyConfig (CMC), contain a Insertion of Sensitive Information into Log File vulnerability. This could allow a local authenticated user with low privileges to read sensitive information and thus circumvent access restrictions. | |||||
CVE-2023-30755 | 2024-09-10 | N/A | 4.4 MEDIUM | ||
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-7 LTE (All versions < V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). The web server of the affected devices do not properly handle the shutdown or reboot request, which could lead to the clean up of certain resources. This could allow a remote attacker with elevated privileges to cause a denial of service condition in the system. | |||||
CVE-2024-45279 | 2024-09-10 | N/A | 6.1 MEDIUM | ||
Due to insufficient input validation, CRM Blueprint Application Builder Panel of SAP NetWeaver Application Server for ABAP allows an unauthenticated attacker to craft a URL link which could embed a malicious JavaScript. When a victim clicks on this link, the script will be executed in the victim's browser giving the attacker the ability to access and/or modify information with no effect on availability of the application. | |||||
CVE-2024-45283 | 2024-09-10 | N/A | 6.0 MEDIUM | ||
SAP NetWeaver AS for Java allows an authorized attacker to obtain sensitive information. The attacker could obtain the username and password when creating an RFC destination. After successful exploitation, an attacker can read the sensitive information but cannot modify or delete the data. | |||||
CVE-2024-41171 | 2024-09-10 | N/A | 8.8 HIGH | ||
A vulnerability has been identified in SINUMERIK 828D V4 (All versions), SINUMERIK 828D V5 (All versions < V5.24), SINUMERIK 840D sl V4 (All versions), SINUMERIK ONE (All versions < V6.24). Affected devices do not properly enforce access restrictions to scripts that are regularly executed by the system with elevated privileges. This could allow an authenticated local attacker to escalate their privileges in the underlying system. | |||||
CVE-2024-45285 | 2024-09-10 | N/A | 5.4 MEDIUM | ||
The RFC enabled function module allows a low privileged user to perform denial of service on any user and also change or delete favourite nodes. By sending a crafted packet in the function module targeting specific parameters, the specific targeted user will no longer have access to any functionality of SAP GUI. There is low impact on integrity and availability of the application. | |||||
CVE-2024-41170 | 2024-09-10 | N/A | 7.8 HIGH | ||
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0015), Tecnomatix Plant Simulation V2404 (All versions < V2404.0004). The affected applications contain a stack based overflow vulnerability while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. | |||||
CVE-2024-44115 | 2024-09-10 | N/A | 4.3 MEDIUM | ||
The RFC enabled function module allows a low privileged user to add URLs to any user's workplace favourites. This vulnerability could be utilized to identify usernames and access information about targeted user's workplaces, and nodes. There is low impact on integrity of the application | |||||
CVE-2024-42380 | 2024-09-10 | N/A | 4.3 MEDIUM | ||
The RFC enabled function module allows a low privileged user to read any user's workplace favourites and user menu along with all the specific data of each node. Usernames can be enumerated by exploiting vulnerability. There is low impact on confidentiality of the application. | |||||
CVE-2024-44113 | 2024-09-10 | N/A | 4.3 MEDIUM | ||
Due to missing authorization checks, SAP Business Warehouse (BEx Analyzer) allows an authenticated attacker to access information over the network which is otherwise restricted. On successful exploitation the attacker can enumerate information causing a limited impact on confidentiality of the application. | |||||
CVE-2024-44116 | 2024-09-10 | N/A | 4.3 MEDIUM | ||
The RFC enabled function module allows a low privileged user to add any workbook to any user's workplace favourites. This vulnerability could be utilized to identify usernames and access information about targeted user's workplaces. There is low impact on integrity of the application. | |||||
CVE-2024-45281 | 2024-09-10 | N/A | 5.8 MEDIUM | ||
SAP BusinessObjects Business Intelligence Platform allows a high privilege user to run client desktop applications even if some of the DLLs are not digitally signed or if the signature is broken. The attacker needs to have local access to the vulnerable system to perform DLL related tasks. This could result in a high impact on confidentiality and integrity of the application. | |||||
CVE-2024-43647 | 2024-09-10 | N/A | 7.5 HIGH | ||
A vulnerability has been identified in SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR30 (6ES7288-1SR30-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR40 (6ES7288-1SR40-0AA1) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA0) (All versions), SIMATIC S7-200 SMART CPU SR60 (6ES7288-1SR60-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST20 (6ES7288-1ST20-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST30 (6ES7288-1ST30-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST40 (6ES7288-1ST40-0AA1) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA0) (All versions), SIMATIC S7-200 SMART CPU ST60 (6ES7288-1ST60-0AA1) (All versions). Affected devices do not properly handle TCP packets with an incorrect structure. This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the network cable of the device needs to be unplugged and re-plugged. | |||||
CVE-2024-44121 | 2024-09-10 | N/A | 4.3 MEDIUM | ||
Under certain conditions Statutory Reports in SAP S/4 HANA allows an attacker with basic privileges to access information which would otherwise be restricted. The vulnerability could expose internal user data that should remain confidential. It does not impact the integrity and availability of the application | |||||
CVE-2024-42371 | 2024-09-10 | N/A | 5.4 MEDIUM | ||
The RFC enabled function module allows a low privileged user to delete the workplace favourites of any user. This vulnerability could be utilized to identify usernames and access information about targeted user's workplaces and nodes. There is low impact on integrity and availability of the application. |