Vulnerabilities (CVE)

Filtered by vendor Rockwellautomation Subscribe
Total 338 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-27476 1 Rockwellautomation 1 Factorytalk Assetcentre 2024-11-21 7.5 HIGH 10.0 CRITICAL
A vulnerability exists in the SaveConfigFile function of the RACompare Service, which may allow for OS command injection. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier.
CVE-2021-27475 1 Rockwellautomation 1 Connected Components Workbench 2024-11-21 6.8 MEDIUM 8.6 HIGH
Rockwell Automation Connected Components Workbench v12.00.00 and prior does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in remote code execution. This vulnerability requires user interaction to be successfully exploited.
CVE-2021-27474 1 Rockwellautomation 1 Factorytalk Assetcentre 2024-11-21 5.0 MEDIUM 10.0 CRITICAL
Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier does not properly restrict all functions relating to IIS remoting services. This vulnerability may allow a remote, unauthenticated attacker to modify sensitive data in FactoryTalk AssetCentre.
CVE-2021-27473 1 Rockwellautomation 1 Connected Components Workbench 2024-11-21 6.9 MEDIUM 6.1 MEDIUM
Rockwell Automation Connected Components Workbench v12.00.00 and prior does not sanitize paths specified within the .ccwarc archive file during extraction. This type of vulnerability is also commonly referred to as a Zip Slip. A local, authenticated attacker can create a malicious .ccwarc archive file that, when opened by Connected Components Workbench, will allow the attacker to gain the privileges of the software. If the software is running at SYSTEM level, the attacker will gain admin level privileges. User interaction is required for this exploit to be successful.
CVE-2021-27472 1 Rockwellautomation 1 Factorytalk Assetcentre 2024-11-21 7.5 HIGH 10.0 CRITICAL
A vulnerability exists in the RunSearch function of SearchService service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier, which may allow for the execution of remote unauthenticated arbitrary SQL statements.
CVE-2021-27471 1 Rockwellautomation 1 Connected Components Workbench 2024-11-21 6.8 MEDIUM 7.7 HIGH
The parsing mechanism that processes certain file types does not provide input sanitization for file paths. This may allow an attacker to craft malicious files that, when opened by Rockwell Automation Connected Components Workbench v12.00.00 and prior, can traverse the file system. If successfully exploited, an attacker could overwrite existing files and create additional files with the same permissions of the Connected Components Workbench software. User interaction is required for this exploit to be successful.
CVE-2021-27470 1 Rockwellautomation 1 Factorytalk Assetcentre 2024-11-21 7.5 HIGH 10.0 CRITICAL
A deserialization vulnerability exists in how the LogService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre.
CVE-2021-27468 1 Rockwellautomation 1 Factorytalk Assetcentre 2024-11-21 7.5 HIGH 10.0 CRITICAL
The AosService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier exposes functions lacking proper authentication. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary SQL statements.
CVE-2021-27466 1 Rockwellautomation 1 Factorytalk Assetcentre 2024-11-21 7.5 HIGH 10.0 CRITICAL
A deserialization vulnerability exists in how the ArchiveService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre.
CVE-2021-27464 1 Rockwellautomation 1 Factorytalk Assetcentre 2024-11-21 7.5 HIGH 10.0 CRITICAL
The ArchiveService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier exposes functions lacking proper authentication. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary SQL statements.
CVE-2021-27462 1 Rockwellautomation 1 Factorytalk Assetcentre 2024-11-21 7.5 HIGH 10.0 CRITICAL
A deserialization vulnerability exists in how the AosService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre.
CVE-2021-27460 1 Rockwellautomation 1 Factorytalk Assetcentre 2024-11-21 7.5 HIGH 10.0 CRITICAL
Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier components contain .NET remoting endpoints that deserialize untrusted data without sufficiently verifying that the resulting data will be valid. This vulnerability may allow a remote, unauthenticated attacker to gain full access to the FactoryTalk AssetCentre main server and all agent machines.
CVE-2021-22665 1 Rockwellautomation 2 Drivetools Add-on Profiles, Drivetools Sp 2024-11-21 7.2 HIGH 7.8 HIGH
Rockwell Automation DriveTools SP v5.13 and below and Drives AOP v4.12 and below both contain a vulnerability that a local attacker with limited privileges may be able to exploit resulting in privilege escalation and complete control of the system.
CVE-2020-6980 1 Rockwellautomation 6 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 3 more 2024-11-21 2.1 LOW 3.3 LOW
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol (SMTP) account data is saved in RSLogix 500, a local attacker with access to a victim’s project may be able to gather SMTP server authentication data as it is written to the project file in cleartext.
CVE-2020-6967 1 Rockwellautomation 1 Factorytalk Services Platform 2024-11-21 10.0 HIGH 9.8 CRITICAL
In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.
CVE-2020-6111 1 Rockwellautomation 2 Micrologix 1100, Micrologix 1100 B Firmware 2024-11-21 5.0 MEDIUM 7.5 HIGH
An exploitable denial-of-service vulnerability exists in the IPv4 functionality of Allen-Bradley MicroLogix 1100 Programmable Logic Controller Systems Series B FRN 16.000, Series B FRN 15.002, Series B FRN 15.000, Series B FRN 14.000, Series B FRN 13.000, Series B FRN 12.000, Series B FRN 11.000 and Series B FRN 10.000. A specially crafted packet can cause a major error, resulting in a denial of service. An attacker can send a malicious packet to trigger this vulnerability.
CVE-2020-6088 1 Rockwellautomation 2 Flex Io 1794-aent\/b, Flex Io 1794-aent\/b Firmware 2024-11-21 5.0 MEDIUM 7.5 HIGH
An exploitable denial of service vulnerability exists in the ENIP Request Path Network Segment functionality of Allen-Bradley Flex IO 1794-AENT/B 4.003. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability.
CVE-2020-6087 1 Rockwellautomation 2 Flex I\/o 1794-aent\/b, Flex I\/o 1794-aent\/b Firmware 2024-11-21 7.8 HIGH 7.5 HIGH
An exploitable denial of service vulnerability exists in the ENIP Request Path Data Segment functionality of Allen-Bradley Flex IO 1794-AENT/B. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability If the ANSI Extended Symbol Segment Sub-Type is supplied, the device treats the byte following as the Data Size in words. When this value represents a size greater than what remains in the packet data, the device enters a fault state where communication with the device is lost and a physical power cycle is required.
CVE-2020-6086 1 Rockwellautomation 2 Flex I\/o 1794-aent\/b, Flex I\/o 1794-aent\/b Firmware 2024-11-21 7.8 HIGH 7.5 HIGH
An exploitable denial of service vulnerability exists in the ENIP Request Path Data Segment functionality of Allen-Bradley Flex IO 1794-AENT/B. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability.If the Simple Segment Sub-Type is supplied, the device treats the byte following as the Data Size in words. When this value represents a size greater than what remains in the packet data, the device enters a fault state where communication with the device is lost and a physical power cycle is required.
CVE-2020-6085 1 Rockwellautomation 1 Flex I\/o 1794-aent 2024-11-21 7.8 HIGH 7.5 HIGH
An exploitable denial of service vulnerability exists in the ENIP Request Path Logical Segment functionality of Allen-Bradley Flex IO 1794-AENT/B 4.003. A specially crafted network request can cause a loss of communications with the device resulting in denial-of-service. An attacker can send a malicious packet to trigger this vulnerability by sending an Electronic Key Segment with less than 0x18 bytes following the Key Format field.