CVE-2025-32969 1 Xwiki 1 Xwiki 2026-06-17 N/A 9.8 CRITICAL
XWiki is a generic wiki platform. In versions starting from 1.8 and prior to 15.10.16, 16.4.6, and 16.10.1, it is possible for a remote unauthenticated user to escape from the HQL execution context and perform a blind SQL injection to execute arbitrary SQL statements on the database backend, including when "Prevent unregistered users from viewing pages, regardless of the page rights" and "Prevent unregistered users from editing pages, regardless of the page rights" options are enabled. Depending on the used database backend, the attacker may be able to not only obtain confidential information such as password hashes from the database, but also execute UPDATE/INSERT/DELETE queries. This issue has been patched in versions 16.10.1, 16.4.6 and 15.10.16. There is no known workaround, other than upgrading XWiki.
CVE-2025-32968 1 Xwiki 1 Xwiki 2026-06-17 N/A 8.8 HIGH
XWiki is a generic wiki platform. In versions starting from 1.6-milestone-1 to before 15.10.16, 16.4.6, and 16.10.1, it is possible for a user with SCRIPT right to escape from the HQL execution context and perform a blind SQL injection to execute arbitrary SQL statements on the database backend. Depending on the used database backend, the attacker may be able to not only obtain confidential information such as password hashes from the database, but also execute UPDATE/INSERT/DELETE queries. This issue has been patched in versions 16.10.1, 16.4.6 and 15.10.16. There is no known workaround, other than upgrading XWiki. The protection added to this REST API is the same as the one used to validate complete select queries, making it more consistent. However, while the script API always had this protection for complete queries, it's important to note that it's a very strict protection and some valid, but complex, queries might suddenly require the author to have programming right.
CVE-2025-32956 1 Miraheze 1 Managewiki 2026-06-17 N/A 8.0 HIGH
ManageWiki is a MediaWiki extension allowing users to manage wikis. Versions before commit f504ed8, are vulnerable to SQL injection when renaming a namespace in Special:ManageWiki/namespaces when using a page prefix (namespace name, which is the current namespace you are renaming) with an injection payload. This issue has been patched in commit f504ed8. A workaround for this vulnerability involves setting `$wgManageWiki['namespaces'] = false;`.
CVE-2025-32924 1 Roninwp 1 Revy 2026-06-17 N/A 8.5 HIGH
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in roninwp Revy revy allows SQL Injection.This issue affects Revy: from n/a through <= 2.1.
CVE-2025-32872 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetOverview' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32871 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'MigrateDatabase' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32870 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetTraces' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32869 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportCertificate' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32868 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ExportCertificate' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32867 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32866 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetLogs' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32865 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateLog' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32864 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32863 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32862 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32861 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32860 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32859 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32858 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
CVE-2025-32857 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockBufferingSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.