Vulnerabilities (CVE)

Filtered by CWE-319
Total 876 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-31193 1 Snapone 1 Orvc 2026-06-17 N/A 7.5 HIGH
Snap One OvrC Pro versions prior to 7.3 use HTTP connections when downloading a program from their servers. Because they do not use HTTPS, OvrC Pro devices are susceptible to exploitation.
CVE-2023-30841 1 Linuxfoundation 1 Baremetal Operator 2026-06-17 N/A 6.0 MEDIUM
Baremetal Operator (BMO) is a bare metal host provisioning integration for Kubernetes. Prior to version 0.3.0, ironic and ironic-inspector deployed within Baremetal Operator using the included `deploy.sh` store their `.htpasswd` files as ConfigMaps instead of Secrets. This causes the plain-text username and hashed password to be readable by anyone having a cluster-wide read-access to the management cluster, or access to the management cluster's Etcd storage. This issue is patched in baremetal-operator PR#1241, and is included in BMO release 0.3.0 onwards. As a workaround, users may modify the kustomizations and redeploy the BMO, or recreate the required ConfigMaps as Secrets per instructions in baremetal-operator PR#1241.
CVE-2023-30602 1 Hitrontech 2 Coda-5310, Coda-5310 Firmware 2026-06-17 N/A 7.5 HIGH
Hitron Technologies CODA-5310’s Telnet function transfers sensitive data in plaintext. An unauthenticated remote attacker can exploit this vulnerability to access credentials of normal users and administrator.
CVE-2023-30565 1 Bd 1 Guardrails Cqi Reporter 2026-06-17 N/A 3.5 LOW
An insecure connection between Systems Manager and CQI Reporter application could expose infusion data to an attacker.
CVE-2023-30515 1 Jenkins 1 Thycotic Devops Secrets Vault 2026-06-17 N/A 7.5 HIGH
Jenkins Thycotic DevOps Secrets Vault Plugin 1.0.0 and earlier does not properly mask (i.e., replace with asterisks) credentials in the build log when push mode for durable task logging is enabled.
CVE-2023-30514 1 Jenkins 1 Azure Key Vault 2026-06-17 N/A 7.5 HIGH
Jenkins Azure Key Vault Plugin 187.va_cd5fecd198a_ and earlier does not properly mask (i.e., replace with asterisks) credentials in the build log when push mode for durable task logging is enabled.
CVE-2023-30513 1 Jenkins 1 Kubernetes 2026-06-17 N/A 7.5 HIGH
Jenkins Kubernetes Plugin 3909.v1f2c633e8590 and earlier does not properly mask (i.e., replace with asterisks) credentials in the build log when push mode for durable task logging is enabled.
CVE-2023-30354 1 Tenda 2 Cp3, Cp3 Firmware 2026-06-17 N/A 9.8 CRITICAL
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 does not defend against physical access to U-Boot via the UART: the Wi-Fi password is shown, and the hardcoded boot password can be inserted for console access.
CVE-2023-2754 1 Cloudflare 1 Warp 2026-06-17 N/A 7.4 HIGH
The Cloudflare WARP client for Windows assigns loopback IPv4 addresses for the DNS Servers, since WARP acts as local DNS server that performs DNS queries in a secure manner, however, if a user is connected to WARP over an IPv6-capable network, te WARP client did not assign loopback IPv6 addresses but Unique Local Addresses, which under certain conditions could point towards unknown devices in the same local network which enables an Attacker to view DNS queries made by the device.
CVE-2023-29681 1 Tenda 2 N301, N301 Firmware 2026-06-17 N/A 5.7 MEDIUM
Cleartext Transmission in cookie:ecos_pw: in Tenda N301 v6.0, firmware v12.03.01.06_pt allows an authenticated attacker on the LAN or WLAN to intercept communications with the router and obtain the password.
CVE-2023-29680 1 Tenda 2 N301, N301 Firmware 2026-06-17 N/A 5.7 MEDIUM
Cleartext Transmission in set-cookie:ecos_pw: Tenda N301 v6.0, Firmware v12.02.01.61_multi allows an authenticated attacker on the LAN or WLAN to intercept communications with the router and obtain the password.
CVE-2023-28616 1 Stormshield 1 Stormshield Network Security 2026-06-17 N/A 7.5 HIGH
An issue was discovered in Stormshield Network Security (SNS) before 4.3.17, 4.4.x through 4.6.x before 4.6.4, and 4.7.x before 4.7.1. It affects user accounts for which the password has an equals sign or space character. The serverd process logs such passwords in cleartext, and potentially sends these logs to the Syslog component.
CVE-2023-28348 2 Faronics, Microsoft 2 Insight, Windows 2026-06-17 N/A 7.4 HIGH
An issue was discovered in Faronics Insight 10.0.19045 on Windows. A suitably positioned attacker could perform a man-in-the-middle attack on either a connected student or teacher, enabling them to intercept student keystrokes or modify executable files being sent from teachers to students.
CVE-2023-27927 1 Sauter-controls 2 Ey-as525f001, Ey-as525f001 Firmware 2026-06-17 N/A 6.5 MEDIUM
An authenticated malicious user could acquire the simple mail transfer protocol (SMTP) Password in cleartext format, despite it being protected and hidden behind asterisks. The attacker could then perform further attacks using the SMTP credentials.
CVE-2023-27861 1 Ibm 1 Maximo Application Suite 2026-06-17 N/A 5.9 MEDIUM
IBM Maximo Application Suite - Manage Component 8.8.0 and 8.9.0 transmits sensitive information in cleartext that could be intercepted by an attacker using man in the middle techniques. IBM X-Force ID: 249208.
CVE-2023-27291 1 Ibm 1 Watson Cp4d Data Stores 2026-06-17 N/A 4.5 MEDIUM
IBM Watson CP4D Data Stores 4.6.0, 4.6.1, 4.6.2, and 4.6.3 does not encrypt sensitive or critical information before storage or transmission which could allow an attacker to obtain sensitive information. IBM X-Force ID: 248740.
CVE-2023-25848 1 Esri 1 Arcgis Server 2026-06-17 N/A 5.3 MEDIUM
ArcGIS Enterprise Server versions 11.0 and below have an information disclosure vulnerability where a remote, unauthorized attacker may submit a crafted query that may result in a low severity information disclosure issue. The information disclosed is limited to a single attribute in a database connection string. No business data is disclosed.
CVE-2023-25437 1 Vtech 2 Vcs754a, Vcs754a Firmware 2026-06-17 N/A 8.8 HIGH
An issue was discovered in vTech VCS754 version 1.1.1.A before 1.1.1.H, allows attackers to gain escalated privileges and gain sensitive information due to cleartext passwords passed in the raw HTML.
CVE-2023-25070 1 Seiko-sol 4 Skybridge Mb-a100, Skybridge Mb-a100 Firmware, Skybridge Mb-a110 and 1 more 2026-06-17 N/A 6.5 MEDIUM
Cleartext transmission of sensitive information exists in SkyBridge MB-A100/110 firmware Ver. 4.2.0 and earlier. If the telnet connection is enabled, a remote unauthenticated attacker may eavesdrop on or alter the administrator's communication to the product.
CVE-2023-25016 1 Couchbase 1 Couchbase Server 2026-06-17 N/A 7.5 HIGH
Couchbase Server before 6.6.6, 7.x before 7.0.5, and 7.1.x before 7.1.2 exposes Sensitive Information to an Unauthorized Actor.