Vulnerabilities (CVE)

Filtered by CWE-20
Total 10721 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-30709 1 Google 1 Android 2024-11-21 5.0 MEDIUM 2.5 LOW
Improper input validation check logic vulnerability in SECRIL prior to SMR Jun-2022 Release 1 allows attackers to trigger crash.
CVE-2022-30535 1 F5 1 Nginx Ingress Controller 2024-11-21 N/A 6.5 MEDIUM
In versions 2.x before 2.3.0 and all versions of 1.x, An attacker authorized to create or update ingress objects can obtain the secrets available to the NGINX Ingress Controller. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
CVE-2022-30331 1 Tigergraph 1 Tigergraph 2024-11-21 N/A 8.8 HIGH
The User-Defined Functions (UDF) feature in TigerGraph 3.6.0 allows installation of a query (in the GSQL query language) without proper validation. Consequently, an attacker can execute arbitrary C++ code. NOTE: the vendor's position is "GSQL was behaving as expected."
CVE-2022-30330 1 Keepkey 2 Keepkey, Keepkey Firmware 2024-11-21 6.9 MEDIUM 6.6 MEDIUM
In the KeepKey firmware before 7.3.2,Flaws in the supervisor interface can be exploited to bypass important security restrictions on firmware operations. Using these flaws, malicious firmware code can elevate privileges, permanently make the device inoperable or overwrite the trusted bootloader code to compromise the hardware wallet across reboots or storage wipes.
CVE-2022-30233 1 Schneider-electric 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more 2024-11-21 4.3 MEDIUM 6.5 MEDIUM
A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-30232 1 Schneider-electric 2 Powerlogic Ion Setup, Powerlogic Ion Setup Firmware 2024-11-21 6.5 MEDIUM 8.0 HIGH
A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-2618 2 Fedoraproject, Google 2 Fedora, Chrome 2024-11-21 N/A 6.5 MEDIUM
Insufficient validation of untrusted input in Internals in Google Chrome prior to 104.0.5112.79 allowed a remote attacker to bypass download restrictions via a malicious file .
CVE-2022-2502 1 Hitachienergy 2 Rtu500, Rtu500 Firmware 2024-11-21 N/A 7.5 HIGH
A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. The vulnerability can only be exploited, if the HCI 60870-5-104 is configured with support for IEC 62351-5 and the CMU contains the license feature ‘Advanced security’ which must be ordered separately. If these preconditions are fulfilled, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a missing input data validation which eventually if exploited causes an internal buffer to overflow in the HCI IEC 60870-5-104 function.
CVE-2022-2479 1 Google 2 Android, Chrome 2024-11-21 N/A 4.3 MEDIUM
Insufficient validation of untrusted input in File in Google Chrome on Android prior to 103.0.5060.134 allowed an attacker who convinced a user to install a malicious app to obtain potentially sensitive information from internal file directories via a crafted HTML page.
CVE-2022-2417 1 Gitlab 1 Gitlab 2024-11-21 N/A 6.2 MEDIUM
Insufficient validation in GitLab CE/EE affecting all versions from 12.10 prior to 15.0.5, 15.1 prior to 15.1.4, and 15.2 prior to 15.2.1 allows an authenticated and authorised user to import a project that includes branch names which are 40 hexadecimal characters, which could be abused in supply chain attacks where a victim pinned to a specific Git commit of the project.
CVE-2022-2047 3 Debian, Eclipse, Netapp 7 Debian Linux, Jetty, Element Plug-in For Vcenter Server and 4 more 2024-11-21 4.0 MEDIUM 2.7 LOW
In Eclipse Jetty versions 9.4.0 thru 9.4.46, and 10.0.0 thru 10.0.9, and 11.0.0 thru 11.0.9 versions, the parsing of the authority segment of an http scheme URI, the Jetty HttpURI class improperly detects an invalid input as a hostname. This can lead to failures in a Proxy scenario.
CVE-2022-29922 1 Hitachienergy 2 Microscada X Sys600, Sys600 2024-11-21 N/A 7.5 HIGH
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. The vulnerability may cause a denial-of-service on the IEC 61850 OPC Server part of the SYS600 product. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
CVE-2022-29897 1 Phoenixcontact 6 Rad-ism-900-en-bd, Rad-ism-900-en-bd-bus, Rad-ism-900-en-bd-bus Firmware and 3 more 2024-11-21 9.0 HIGH 9.1 CRITICAL
On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the traceroute utility integrated in the WebUI to execute arbitrary code with root privileges on the OS due to an improper input validation in all versions of the firmware.
CVE-2022-29892 1 Cybozu 1 Garoon 2024-11-21 4.0 MEDIUM 6.5 MEDIUM
Improper input validation vulnerability in Space of Cybozu Garoon 4.0.0 to 5.5.1 allows a remote authenticated attacker to repeatedly display errors in certain functions and cause a denial-of-service (DoS).
CVE-2022-29850 1 Lexmark 234 B2236, B2236 Firmware, B2338 and 231 more 2024-11-21 N/A 8.1 HIGH
Various Lexmark products through 2022-04-27 allow an attacker who has already compromised an affected Lexmark device to maintain persistence across reboots.
CVE-2022-29613 1 Sap 1 Employee Self Service 2024-11-21 4.0 MEDIUM 4.3 MEDIUM
Due to insufficient input validation, SAP Employee Self Service allows an authenticated attacker with user privileges to alter employee number. On successful exploitation, the attacker can view personal details of other users causing a limited impact on confidentiality of the application.
CVE-2022-29494 1 Intel 58 C621a, C627a, C629a and 55 more 2024-11-21 N/A 6.5 MEDIUM
Improper input validation in firmware for OpenBMC in some Intel(R) platforms before versions egs-0.91-179 and bhs-04-45 may allow an authenticated user to potentially enable denial of service via network access.
CVE-2022-29492 1 Hitachienergy 2 Microscada X Sys600, Sys600 2024-11-21 N/A 5.3 MEDIUM
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. Upon receiving a malformed IEC 104 TCP packet, the malformed packet is dropped, however the TCP connection is left open. This may cause a denial-of-service if the affected connection is left open. This issue affects: Hitachi Energy MicroSCADA Pro SYS600 version 9.4 FP2 Hotfix 4 and earlier versions Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.0:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
CVE-2022-29479 1 F5 12 Big-ip Access Policy Manager, Big-ip Advanced Firewall Manager, Big-ip Analytics and 9 more 2024-11-21 5.0 MEDIUM 5.3 MEDIUM
On F5 BIG-IP 15.1.x versions prior to 15.1.5.1, 14.1.x versions prior to 14.1.4.6, 13.1.x versions prior to 13.1.5, and all versions of 12.1.x and 11.6.x, and F5 BIG-IQ Centralized Management all versions of 8.x and 7.x, when an IPv6 self IP address is configured and the ipv6.strictcompliance database key is enabled (disabled by default) on a BIG-IP system, undisclosed packets may cause decreased performance. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
CVE-2022-29243 1 Nextcloud 1 Nextcloud Server 2024-11-21 4.0 MEDIUM 4.3 MEDIUM
Nextcloud Server is the file server software for Nextcloud, a self-hosted productivity platform. Prior to versions 22.2.7 and 23.0.4, missing input-size validation of new session names allows users to create app passwords with long names. These long names are then loaded into memory on usage, resulting in impacted performance. Versions 22.2.7 and 23.0.4 contain a fix for this issue. There are currently no known workarounds available.