Total
11398 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2025-43293 | 1 Apple | 1 Macos | 2026-06-17 | N/A | 5.5 MEDIUM |
| The issue was addressed with improved input validation. This issue is fixed in macOS Sequoia 15.7, macOS Sonoma 14.8, macOS Tahoe 26. An app may be able to access sensitive user data. | |||||
| CVE-2025-43253 | 1 Apple | 1 Macos | 2026-06-17 | N/A | 9.8 CRITICAL |
| This issue was addressed with improved input validation. This issue is fixed in macOS Sequoia 15.6, macOS Sonoma 14.7.7. A malicious app may be able to launch arbitrary binaries on a trusted device. | |||||
| CVE-2025-43234 | 1 Apple | 6 Ipados, Iphone Os, Macos and 3 more | 2026-06-17 | N/A | 9.8 CRITICAL |
| Multiple memory corruption issues were addressed with improved input validation. This issue is fixed in iOS 18.6 and iPadOS 18.6, macOS Sequoia 15.6, tvOS 18.6, visionOS 2.6, watchOS 11.6. Processing a maliciously crafted texture may lead to unexpected app termination. | |||||
| CVE-2025-43223 | 1 Apple | 6 Ipados, Iphone Os, Macos and 3 more | 2026-06-17 | N/A | 7.5 HIGH |
| A denial-of-service issue was addressed with improved input validation. This issue is fixed in iOS 18.6 and iPadOS 18.6, iPadOS 17.7.9, macOS Sequoia 15.6, macOS Sonoma 14.7.7, macOS Ventura 13.7.7, tvOS 18.6, visionOS 2.6, watchOS 11.6. A non-privileged user may be able to modify restricted network settings. | |||||
| CVE-2025-43195 | 1 Apple | 1 Macos | 2026-06-17 | N/A | 5.5 MEDIUM |
| An issue existed in the handling of environment variables. This issue was addressed with improved validation. This issue is fixed in macOS Sequoia 15.6, macOS Sonoma 14.7.7, macOS Ventura 13.7.7. An app may be able to access sensitive user data. | |||||
| CVE-2025-41379 | 2026-06-17 | N/A | N/A | ||
| The Intellian C700 web panel allows you to add firewall rules. Each of these rules has an associated ID, but there is a problem when adding a new rule, the ID used to create the database entry may be different from the JSON ID. If the rule needs to be deleted later, the system will use the JSON ID and therefore fail. This can be exploited by an attacker to create rules that cannot be deleted unless the device is reset to factory defaults. | |||||
| CVE-2025-41378 | 2026-06-17 | N/A | N/A | ||
| The SSID field is not parsed correctly and can be used to inject commands into the hostpad.conf file. This can be exploited by an attacker to extend his knowledge of the system and compromise other devices. The information is filtered by the logs function of the web panel. | |||||
| CVE-2025-41257 | 2026-06-17 | N/A | 4.8 MEDIUM | ||
| Suprema’s BioStar 2 in version 2.9.11.6 allows users to set new password without providing the current one. Exploiting this flaw combined with other vulnerabilities can lead to unauthorized account access and potential system compromise. | |||||
| CVE-2025-40935 | 2026-06-17 | N/A | 4.3 MEDIUM | ||
| A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.10.1), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.10.1), RUGGEDCOM RS416v2 V5.X (All versions < V5.10.1), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.10.1), RUGGEDCOM RSG2288 V5.X (All versions < V5.10.1), RUGGEDCOM RSG2300 V5.X (All versions < V5.10.1), RUGGEDCOM RSG2300P V5.X (All versions < V5.10.1), RUGGEDCOM RSG2488 V5.X (All versions < V5.10.1), RUGGEDCOM RSG907R (All versions < V5.10.1), RUGGEDCOM RSG908C (All versions < V5.10.1), RUGGEDCOM RSG909R (All versions < V5.10.1), RUGGEDCOM RSG910C (All versions < V5.10.1), RUGGEDCOM RSG920P V5.X (All versions < V5.10.1), RUGGEDCOM RSL910 (All versions < V5.10.1), RUGGEDCOM RST2228 (All versions < V5.10.1), RUGGEDCOM RST2228P (All versions < V5.10.1), RUGGEDCOM RST916C (All versions < V5.10.1), RUGGEDCOM RST916P (All versions < V5.10.1). Affected devices do not properly validate input during the TLS certificate upload process of the web service. This could allow an authenticated remote attacker to trigger a device crash and reboot, leading to a temporary Denial of Service on the device. | |||||
| CVE-2025-40846 | 2026-06-17 | N/A | N/A | ||
| Improper Input Validation, the returnUrl parameter in Account Security Settings lacks proper input validation, allowing attackers to redirect users to malicious websites (Open Redirect) and inject JavaScript code to perform cross site scripting attack. The vulnerability affects Halo versions up to 2.174.101 and all versions between 2.175.1 and 2.184.21 | |||||
| CVE-2025-40836 | 1 Ericsson | 2 Indoor Connect 8855, Indoor Connect 8855 Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| Ericsson Indoor Connect 8855 contains an improper input validation vulnerability which if exploited can allow an attacker to execute commands with escalated privileges. | |||||
| CVE-2025-40831 | 1 Siemens | 1 Sinec Security Monitor | 2026-06-17 | N/A | 6.5 MEDIUM |
| A vulnerability has been identified in SINEC Security Monitor (All versions < V4.10.0). The affected application lacks input validation of date parameter in report generation functionality. This could allow an authenticated, lowly privileged attacker to cause denial of service condition of the report functionality. | |||||
| CVE-2025-40746 | 1 Siemens | 1 Simatic Rtls Locating Manager | 2026-06-17 | N/A | 9.1 CRITICAL |
| A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V3.2). Affected products do not properly validate input for a backup script. This could allow an authenticated remote attacker with high privileges in the application to execute arbitrary code with 'NT Authority/SYSTEM' privileges. | |||||
| CVE-2025-40593 | 1 Siemens | 2 Simatic Cn 4100, Simatic Cn 4100 Firmware | 2026-06-17 | N/A | 6.5 MEDIUM |
| A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0). The affected application allows to control the device by storing arbitrary files in the SFTP folder of the device. This could allow an attacker to cause a denial of service condition. | |||||
| CVE-2025-40556 | 2026-06-17 | N/A | 6.5 MEDIUM | ||
| A vulnerability has been identified in BACnet ATEC 550-440 (All versions), BACnet ATEC 550-441 (All versions), BACnet ATEC 550-445 (All versions), BACnet ATEC 550-446 (All versions). Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an attacker residing in the same BACnet network to send a specially crafted MSTP message that results in a denial of service condition of the targeted device. A power cycle is required to restore the device's normal operation. | |||||
| CVE-2025-3898 | 2026-06-17 | N/A | 6.5 MEDIUM | ||
| CWE-20: Improper Input Validation vulnerability exists that could cause Denial of Service when an authenticated malicious user sends HTTPS request containing invalid data type to the webserver. | |||||
| CVE-2025-3885 | 1 Samsung | 2 Harman Mgu21, Harman Mgu21 Firmware | 2026-06-17 | N/A | 6.5 MEDIUM |
| Harman Becker MGU21 Bluetooth Improper Input Validation Denial-of-Service Vulnerability. This vulnerability allows network-adjacent attackers to create a denial-of-service condition on affected installations of Harman Becker MGU21 devices. Authentication is not required to exploit this vulnerability. The specific flaw exists within the Bluetooth stack of the BCM89359 chipset. The issue results from the lack of proper validation of Bluetooth frames. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-23942. | |||||
| CVE-2025-3837 | 2026-06-17 | N/A | N/A | ||
| An improper input validation vulnerability is identified in the End of Life (EOL) OVA based connect component which is deployed for installation purposes in the customer internal network. This EOL component was deprecated in September 2023 with end of support extended till January 2024. Under certain circumstances, an actor can manipulate a specific request parameter and inject code execution payload which could lead to a remote code execution on the infrastructure hosting this component. | |||||
| CVE-2025-3777 | 1 Huggingface | 1 Transformers | 2026-06-17 | N/A | 3.5 LOW |
| Hugging Face Transformers versions up to 4.49.0 are affected by an improper input validation vulnerability in the `image_utils.py` file. The vulnerability arises from insecure URL validation using the `startswith()` method, which can be bypassed through URL username injection. This allows attackers to craft URLs that appear to be from YouTube but resolve to malicious domains, potentially leading to phishing attacks, malware distribution, or data exfiltration. The issue is fixed in version 4.52.1. | |||||
| CVE-2025-3677 | 2026-06-17 | 4.3 MEDIUM | 5.3 MEDIUM | ||
| A vulnerability classified as critical was found in lm-sys fastchat up to 0.2.36. This vulnerability affects the function split_files/apply_delta_low_cpu_mem of the file fastchat/model/apply_delta.py. The manipulation leads to deserialization. An attack has to be approached locally. | |||||
