Total
37 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2024-40113 | 2025-06-02 | N/A | 6.5 MEDIUM | ||
Sitecom WLX-2006 Wall Mount Range Extender N300 v.1.5 and before is vulnerable to Use of Default Credentials. | |||||
CVE-2023-43844 | 1 Aten | 2 Pe6208, Pe6208 Firmware | 2025-05-30 | N/A | 8.0 HIGH |
Aten PE6208 2.3.228 and 2.4.232 have default credentials for the privileged web interface account. The user is not asked to change the credentials after first login. If not changed, attackers can log in to the web interface and gain administrator privileges. | |||||
CVE-2025-5124 | 2025-05-28 | 7.6 HIGH | 8.1 HIGH | ||
A vulnerability classified as critical has been found in Sony SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N and SNC-RX570N up to 1.30. This affects an unknown part of the component Administrative Interface. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. It is recommended to change the configuration settings. The vendor was contacted early about this issue. They confirmed the existence but pointed out that they "have published the 'Hardening Guide' on the Web from July 2018 to January 2025 and have thoroughly informed customers of the recommendation to change their initial passwords". | |||||
CVE-2025-1531 | 2025-05-16 | N/A | 6.5 MEDIUM | ||
Authentication credentials leakage vulnerability in Hitachi Ops Center Analyzer viewpoint.This issue affects Hitachi Ops Center Analyzer viewpoint: from 10.0.0-00 before 11.0.4-00. | |||||
CVE-2025-22460 | 2025-05-13 | N/A | 7.8 HIGH | ||
Default credentials in Ivanti Cloud Services Application before version 5.0.5 allows a local authenticated attacker to escalate their privileges. | |||||
CVE-2024-54015 | 2025-05-13 | N/A | 7.5 HIGH | ||
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials. | |||||
CVE-2025-0482 | 1 Native-php-cms Project | 1 Native-php-cms | 2025-04-29 | 7.5 HIGH | 7.3 HIGH |
A vulnerability, which was classified as critical, was found in Fanli2012 native-php-cms 1.0. This affects an unknown part of the file /fladmin/user_recoverpwd.php. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2024-46899 | 2025-04-23 | N/A | 7.1 HIGH | ||
Hitachi Ops Center Common Services within Hitachi Ops Center Analyzer viewpoint OVF contains an authentication credentials leakage vulnerability.This issue affects Hitachi Ops Center Common Services: from 10.0.0-00 before 11.0.0-04; Hitachi Ops Center Analyzer viewpoint OVF: from 10.0.0-00 before 11.0.0-04. | |||||
CVE-2023-40704 | 1 Philips | 1 Vue Pacs | 2025-04-09 | N/A | 6.8 MEDIUM |
The product does not require unique and complex passwords to be created during installation. Using Philips's default password could jeopardize the PACS system if the password was hacked or leaked. An attacker could gain access to the database impacting system availability and data integrity. | |||||
CVE-2024-4622 | 2025-03-27 | N/A | N/A | ||
If misconfigured, alpitronic Hypercharger EV charging devices can expose a web interface protected by authentication. If the default credentials are not changed, an attacker can use public knowledge to access the device as an administrator. | |||||
CVE-2025-30139 | 2025-03-25 | N/A | 9.8 CRITICAL | ||
An issue was discovered on G-Net Dashcam BB GONX devices. Default credentials for SSID cannot be changed. It broadcasts a fixed SSID with default credentials that cannot be changed. This allows any nearby attacker to connect to the dashcam's network without restriction. Once connected, an attacker can sniff on connected devices such as the user's smartphone. The SSID is also always broadcasted. | |||||
CVE-2025-2398 | 2025-03-18 | 8.3 HIGH | 7.2 HIGH | ||
A vulnerability was found in China Mobile P22g-CIac, ZXWT-MIG-P4G4V, ZXWT-MIG-P8G8V, GT3200-4G4P and GT3200-8G8P up to 20250305. It has been rated as critical. This issue affects some unknown processing of the component CLI su Command Handler. The manipulation leads to use of default credentials. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2025-2341 | 2025-03-16 | 1.8 LOW | 3.1 LOW | ||
A vulnerability was found in IROAD Dash Cam X5 up to 20250203. It has been rated as problematic. This issue affects some unknown processing of the component SSID. The manipulation leads to use of default credentials. The attack needs to be initiated within the local network. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2025-2119 | 2025-03-09 | 1.2 LOW | 2.0 LOW | ||
A vulnerability was found in Thinkware Car Dashcam F800 Pro up to 20250226. It has been declared as problematic. This vulnerability affects unknown code of the component Device Registration Handler. The manipulation leads to use of default credentials. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | |||||
CVE-2024-13893 | 2025-03-06 | N/A | N/A | ||
Smartwares cameras CIP-37210AT and C724IP, as well as others which share the same firmware in versions up to 3.3.0, might share same credentials for telnet service. Hash of the password can be retrieved through physical access to SPI connected memory. For the telnet service to be enabled, the inserted SD card needs to have a folder with a specific name created. Two products were tested, but since the vendor has not replied to reports, patching status remains unknown, as well as groups of devices and firmware ranges in which the same password is shared. Newer firmware versions might be vulnerable as well. | |||||
CVE-2025-1160 | 2025-02-18 | 7.5 HIGH | 7.3 HIGH | ||
A vulnerability was found in SourceCodester Employee Management System 1.0. It has been rated as critical. Affected by this issue is some unknown functionality of the file index.php. The manipulation of the argument username/password leads to use of default credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
CVE-2024-12013 | 2025-02-13 | N/A | 7.6 HIGH | ||
A CWE-1392 “Use of Default Credentials” was discovered affecting the 130.8005 TCP/IP Gateway running firmware version 12h. The device exposes an FTP server with default and easy-to-guess admin credentials. A remote attacker capable of interacting with the FTP server could gain access and perform changes over resources exposed by the service such as configuration files where password hashes are saved or where network settings are stored. | |||||
CVE-2024-5245 | 1 Netgear | 1 Prosafe Network Management System | 2025-02-11 | N/A | 7.8 HIGH |
NETGEAR ProSAFE Network Management System Default Credentials Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of NETGEAR ProSAFE Network Management System. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the product installer. The issue results from the use of default MySQL credentials. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-22755. | |||||
CVE-2025-23012 | 2025-02-03 | N/A | 7.5 HIGH | ||
Fedora Repository 3.8.x includes a service account (fedoraIntCallUser) with default credentials and privileges to read read local files by manipulating datastreams. Fedora Repository 3.8.1 was released on 2015-06-11 and is no longer maintained. Migrate to a currently supported version (6.5.1 as of 2025-01-23). | |||||
CVE-2024-12902 | 2024-12-23 | N/A | 8.4 HIGH | ||
ANCHOR from Global Wisdom Software is an integrated product running on a Windows virtual machine. The underlying Windows OS of the product contains high-privilege service accounts. If these accounts use default passwords, attackers could remotely log in to the virtual machine using the default credentials. |