Total
2809 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2025-40634 | 2026-06-17 | N/A | N/A | ||
| Stack-based buffer overflow vulnerability in the 'conn-indicator' binary running as root on the TP-Link Archer AX50 router, in firmware versions prior to 1.0.15 build 241203 rel61480. This vulnerability allows an attacker to execute arbitrary code on the device over LAN and WAN networks. | |||||
| CVE-2025-40601 | 1 Sonicwall | 33 Nsa 2700, Nsa 2800, Nsa 3700 and 30 more | 2026-06-17 | N/A | 7.5 HIGH |
| A Stack-based buffer overflow vulnerability in the SonicOS SSLVPN service allows a remote unauthenticated attacker to cause Denial of Service (DoS), which could cause an impacted firewall to crash. | |||||
| CVE-2025-40596 | 1 Sonicwall | 6 Sma 210, Sma 210 Firmware, Sma 410 and 3 more | 2026-06-17 | N/A | 7.3 HIGH |
| A Stack-based buffer overflow vulnerability in the SMA100 series web interface allows remote, unauthenticated attacker to cause Denial of Service (DoS) or potentially results in code execution. | |||||
| CVE-2025-40580 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-06-17 | N/A | 6.7 MEDIUM |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices are vulnerable to a stack-based buffer overflow. This could allow a non-privileged local attacker to execute arbitrary code on the device or to cause a denial of service condition. | |||||
| CVE-2025-40579 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-06-17 | N/A | 6.7 MEDIUM |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices are vulnerable to a stack-based buffer overflow. This could allow a non-privileged local attacker to execute arbitrary code on the device or to cause a denial of service condition. | |||||
| CVE-2025-3916 | 2026-06-17 | N/A | N/A | ||
| CWE-121: Stack-based Buffer Overflow vulnerability exists that could cause local attackers being able to exploit these issues to potentially execute arbitrary code while the end user opens a malicious project file (SSD file) provided by the attacker. | |||||
| CVE-2025-3887 | 2 Debian, Gstreamer | 2 Debian Linux, Gstreamer | 2026-06-17 | N/A | 8.8 HIGH |
| GStreamer H265 Codec Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of GStreamer. Interaction with this library is required to exploit this vulnerability but attack vectors may vary depending on the implementation. The specific flaw exists within the parsing of H265 slice headers. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-26596. | |||||
| CVE-2025-3820 | 1 Tenda | 4 I24, I24 Firmware, W12 and 1 more | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644) and classified as critical. Affected by this issue is the function cgiSysUplinkCheckSet of the file /bin/httpd. The manipulation of the argument hostIp1/hostIp2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-3803 | 1 Tenda | 4 I24, I24 Firmware, W12 and 1 more | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644). It has been rated as critical. This issue affects the function cgiSysScheduleRebootSet of the file /bin/httpd. The manipulation of the argument rebootDate leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-3802 | 1 Tenda | 4 I24, I24 Firmware, W12 and 1 more | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644). It has been declared as critical. This vulnerability affects the function cgiPingSet of the file /bin/httpd. The manipulation of the argument pingIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-3785 | 1 Dlink | 2 Dwr-m961, Dwr-m961 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability has been found in D-Link DWR-M961 1.1.36 and classified as critical. This vulnerability affects unknown code of the file /boafrm/formStaticDHCP of the component Authorization Interface. The manipulation of the argument Hostname leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.1.49 is able to address this issue. It is recommended to upgrade the affected component. | |||||
| CVE-2025-3714 | 2026-06-17 | N/A | 9.8 CRITICAL | ||
| The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to execute arbitrary code on the device. | |||||
| CVE-2025-3711 | 2026-06-17 | N/A | 9.8 CRITICAL | ||
| The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to execute arbitrary code on the device. | |||||
| CVE-2025-3710 | 2026-06-17 | N/A | 9.8 CRITICAL | ||
| The LCD KVM over IP Switch CL5708IM has a Stack-based Buffer Overflow vulnerability in firmware versions prior to v2.2.215, allowing unauthenticated remote attackers to exploit this vulnerability to execute arbitrary code on the device. | |||||
| CVE-2025-3693 | 1 Tenda | 2 W12, W12 Firmware | 2026-06-17 | 9.0 HIGH | 8.8 HIGH |
| A vulnerability was found in Tenda W12 3.0.0.5. It has been rated as critical. Affected by this issue is the function cgiWifiRadioSet of the file /bin/httpd. The manipulation leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-3588 | 2026-06-17 | 4.3 MEDIUM | 5.3 MEDIUM | ||
| A vulnerability, which was classified as problematic, has been found in joelittlejohn jsonschema2pojo 1.2.2. This issue affects the function apply of the file org/jsonschema2pojo/rules/SchemaRule.java of the component JSON File Handler. The manipulation leads to stack-based buffer overflow. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2025-3538 | 1 Dlink | 2 Di-8100, Di-8100 Firmware | 2026-06-17 | 8.3 HIGH | 8.8 HIGH |
| A vulnerability was found in D-Link DI-8100 16.07.26A1. It has been rated as critical. This issue affects the function auth_asp of the file /auth.asp of the component jhttpd. The manipulation of the argument callback leads to stack-based buffer overflow. The attack needs to be approached within the local network. The exploit has been disclosed to the public and may be used. | |||||
| CVE-2025-3484 | 1 Meddream | 1 Pacs Server | 2026-06-17 | N/A | 9.8 CRITICAL |
| MedDream PACS Server DICOM File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of MedDream PACS Server. Authentication is not required to exploit this vulnerability. The specific flaw exists within the parsing of DICOM files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the service account. Was ZDI-CAN-25853. | |||||
| CVE-2025-3483 | 1 Meddream | 1 Pacs Server | 2026-06-17 | N/A | 7.8 HIGH |
| MedDream PACS Server DICOM File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of MedDream PACS Server. Authentication is not required to exploit this vulnerability. The specific flaw exists within the parsing of DICOM files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the service account. Was ZDI-CAN-25825. | |||||
| CVE-2025-3482 | 1 Meddream | 1 Pacs Server | 2026-06-17 | N/A | 7.8 HIGH |
| MedDream PACS Server DICOM File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of MedDream PACS Server. Authentication is not required to exploit this vulnerability. The specific flaw exists within the parsing of DICOM files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the service account. Was ZDI-CAN-25826. | |||||
