Vulnerabilities (CVE)

Filtered by CWE-119
Total 12704 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2025-11495 1 Gnu 1 Binutils 2025-10-14 1.7 LOW 3.3 LOW
A vulnerability was determined in GNU Binutils 2.45. The affected element is the function elf_x86_64_relocate_section of the file elf64-x86-64.c of the component Linker. This manipulation causes heap-based buffer overflow. The attack can only be executed locally. The exploit has been publicly disclosed and may be utilized. Patch name: 6b21c8b2ecfef5c95142cbc2c32f185cb1c26ab0. To fix this issue, it is recommended to deploy a patch.
CVE-2025-11494 1 Gnu 1 Binutils 2025-10-14 1.7 LOW 3.3 LOW
A vulnerability was found in GNU Binutils 2.45. Impacted is the function _bfd_x86_elf_late_size_sections of the file bfd/elfxx-x86.c of the component Linker. The manipulation results in out-of-bounds read. The attack needs to be approached locally. The exploit has been made public and could be used. The patch is identified as b6ac5a8a5b82f0ae6a4642c8d7149b325f4cc60a. A patch should be applied to remediate this issue.
CVE-2025-11414 1 Gnu 1 Binutils 2025-10-14 1.7 LOW 3.3 LOW
A vulnerability was determined in GNU Binutils 2.45. Affected by this vulnerability is the function get_link_hash_entry of the file bfd/elflink.c of the component Linker. This manipulation causes out-of-bounds read. The attack can only be executed locally. The exploit has been publicly disclosed and may be utilized. Upgrading to version 2.46 addresses this issue. Patch name: aeaaa9af6359c8e394ce9cf24911fec4f4d23703. It is advisable to upgrade the affected component.
CVE-2025-11413 1 Gnu 1 Binutils 2025-10-14 1.7 LOW 3.3 LOW
A vulnerability was found in GNU Binutils 2.45. Affected is the function elf_link_add_object_symbols of the file bfd/elflink.c of the component Linker. The manipulation results in out-of-bounds read. The attack needs to be approached locally. The exploit has been made public and could be used. Upgrading to version 2.46 is able to address this issue. The patch is identified as 72efdf166aa0ed72ecc69fc2349af6591a7a19c0. Upgrading the affected component is advised.
CVE-2025-11527 1 Tenda 2 Ac7, Ac7 Firmware 2025-10-14 9.0 HIGH 8.8 HIGH
A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
CVE-2025-11526 1 Tenda 2 Ac7, Ac7 Firmware 2025-10-14 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used.
CVE-2025-11412 1 Gnu 1 Binutils 2025-10-14 1.7 LOW 3.3 LOW
A vulnerability has been found in GNU Binutils 2.45. This impacts the function bfd_elf_gc_record_vtentry of the file bfd/elflink.c of the component Linker. The manipulation leads to out-of-bounds read. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. The identifier of the patch is 047435dd988a3975d40c6626a8f739a0b2e154bc. To fix this issue, it is recommended to deploy a patch.
CVE-2025-10948 2025-10-13 9.0 HIGH 8.8 HIGH
A vulnerability has been found in MikroTik RouterOS 7. This affects the function parse_json_element of the file /rest/ip/address/print of the component libjson.so. The manipulation leads to buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 7.20.1 and 7.21beta2 mitigates this issue. You should upgrade the affected component. The vendor replied: "Our bug tracker reports that your issue has been fixed. This means that we plan to release a RouterOS update with this fix. Make sure to upgrade to the next release when it comes out."
CVE-2025-1364 1 Escanav 1 Escan Anti-virus 2025-10-10 4.3 MEDIUM 5.3 MEDIUM
A vulnerability has been found in MicroWord eScan Antivirus 7.0.32 on Linux and classified as critical. Affected by this vulnerability is the function passPrompt of the component USB Protection Service. The manipulation leads to stack-based buffer overflow. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-11525 1 Tenda 2 Ac7, Ac7 Firmware 2025-10-09 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-11524 1 Tenda 2 Ac7, Ac7 Firmware 2025-10-09 9.0 HIGH 8.8 HIGH
A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be used.
CVE-2025-11528 1 Tenda 2 Ac7, Ac7 Firmware 2025-10-09 9.0 HIGH 8.8 HIGH
A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.
CVE-2025-0720 1 Escanav 1 Escan Anti-virus 2025-10-09 1.7 LOW 3.3 LOW
A vulnerability was found in Microword eScan Antivirus 7.0.32 on Linux. It has been rated as problematic. Affected by this issue is the function removeExtraSlashes of the file /opt/MicroWorld/sbin/rtscanner of the component Folder Watch List Handler. The manipulation leads to stack-based buffer overflow. The attack needs to be approached locally. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-1366 1 Escanav 1 Escan Anti-virus 2025-10-09 4.3 MEDIUM 5.3 MEDIUM
A vulnerability was found in MicroWord eScan Antivirus 7.0.32 on Linux and classified as critical. Affected by this issue is the function strcpy of the component VirusPopUp. The manipulation leads to stack-based buffer overflow. The attack needs to be approached locally. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-9525 1 Linksys 2 E1700, E1700 Firmware 2025-10-09 9.0 HIGH 8.8 HIGH
A flaw has been found in Linksys E1700 1.0.0.4.003. Affected by this vulnerability is the function setWan of the file /goform/setWan. This manipulation of the argument DeviceName/lanIp causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-9526 1 Linksys 2 E1700, E1700 Firmware 2025-10-09 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Linksys E1700 1.0.0.4.003. Affected by this issue is the function setSysAdm of the file /goform/setSysAdm. Such manipulation of the argument rm_port leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-9527 1 Linksys 2 E1700, E1700 Firmware 2025-10-09 9.0 HIGH 8.8 HIGH
A vulnerability was found in Linksys E1700 1.0.0.4.003. This affects the function QoSSetup of the file /goform/QoSSetup. Performing manipulation of the argument ack_policy results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-11356 1 Tenda 2 Ac23, Ac23 Firmware 2025-10-09 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC23 up to 16.03.07.52. Affected by this issue is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. It is possible to launch the attack remotely. The exploit has been made public and could be used.
CVE-2025-11385 1 Tenda 2 Ac20, Ac20 Firmware 2025-10-09 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda AC20 up to 16.03.08.12. The affected element is the function sscanf of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-11386 1 Tenda 2 Ac15, Ac15 Firmware 2025-10-09 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC15 15.03.05.18. The impacted element is an unknown function of the file /goform/SetDDNSCfg of the component POST Parameter Handler. The manipulation of the argument ddnsEn results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.