Nefteprodukttekhnika BUK TS-G Gas Station Automation System 2.9.1 through 2.10.2 on Linux contains an Improper Authentication vulnerability (CWE-287) in the system configuration module. The /php/ajax-login.php endpoint returns userid=1 (administrator) in response to any HTTP POST request that supplies arbitrary credentials (e.g., action=dologin&login=<any_value>&pwd=<any_value>), and subsequent privileged endpoints under /php/ajax-main.php and /modules/* do not validate a server-side session. A remote unauthenticated attacker can invoke any administrative action exposed by the configuration module, including reading and modifying user rules, fuel tank gauges, fuel dispensers, relays, cash registers, bank terminals, fuel cards, price and customer displays, cash collection, and pricing rules.
References
Configurations
No configuration.
History
13 Jun 2026, 18:16
| Type | Values Removed | Values Added |
|---|---|---|
| New CVE |
Information
Published : 2026-06-13 18:16
Updated : 2026-06-13 18:16
NVD link : CVE-2026-12183
Mitre link : CVE-2026-12183
CVE.ORG link : CVE-2026-12183
JSON object : View
Products Affected
No product.