CVE-2024-4116

A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this vulnerability is the function formDelDhcpRule of the file /goform/DelDhcpRule. The manipulation of the argument delDhcpIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261859. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Link Resource
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formDelDhcpRule.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.261859 Permissions Required Third Party Advisory VDB Entry
https://vuldb.com/?id.261859 Third Party Advisory VDB Entry
https://vuldb.com/?submit.317819 Third Party Advisory VDB Entry
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formDelDhcpRule.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.261859 Permissions Required Third Party Advisory VDB Entry
https://vuldb.com/?id.261859 Third Party Advisory VDB Entry
https://vuldb.com/?submit.317819 Third Party Advisory VDB Entry
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*
cpe:2.3:h:tenda:w15e:-:*:*:*:*:*:*:*

History

15 Jan 2025, 18:42

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formDelDhcpRule.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formDelDhcpRule.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.261859 - () https://vuldb.com/?ctiid.261859 - Permissions Required, Third Party Advisory, VDB Entry
References () https://vuldb.com/?id.261859 - () https://vuldb.com/?id.261859 - Third Party Advisory, VDB Entry
References () https://vuldb.com/?submit.317819 - () https://vuldb.com/?submit.317819 - Third Party Advisory, VDB Entry
CWE CWE-787
First Time Tenda w15e
Tenda
Tenda w15e Firmware
CPE cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*
cpe:2.3:h:tenda:w15e:-:*:*:*:*:*:*:*

21 Nov 2024, 09:42

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formDelDhcpRule.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formDelDhcpRule.md -
References () https://vuldb.com/?ctiid.261859 - () https://vuldb.com/?ctiid.261859 -
References () https://vuldb.com/?id.261859 - () https://vuldb.com/?id.261859 -
References () https://vuldb.com/?submit.317819 - () https://vuldb.com/?submit.317819 -

14 May 2024, 15:42

Type Values Removed Values Added
Summary
  • (es) Una vulnerabilidad ha sido encontrada en Tenda W15E 15.11.0.14 y clasificada como crítica. La función formDelDhcpRule del archivo /goform/DelDhcpRule es afectada por esta vulnerabilidad. La manipulación del argumento delDhcpIndex provoca un desbordamiento de búfer en la región stack de la memoria. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al público y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-261859. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera.

24 Apr 2024, 16:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-04-24 16:15

Updated : 2025-01-15 18:42


NVD link : CVE-2024-4116

Mitre link : CVE-2024-4116

CVE.ORG link : CVE-2024-4116


JSON object : View

Products Affected

tenda

  • w15e
  • w15e_firmware
CWE
CWE-121

Stack-based Buffer Overflow

CWE-787

Out-of-bounds Write