Show plain JSON{"id": "CVE-2018-5448", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 2.7, "accessVector": "ADJACENT_NETWORK", "vectorString": "AV:A/AC:L/Au:S/C:P/I:N/A:N", "authentication": "SINGLE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "LOW", "obtainAllPrivilege": false, "exploitabilityScore": 5.1, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV30": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 5.7, "attackVector": "ADJACENT_NETWORK", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "impactScore": 3.6, "exploitabilityScore": 2.1}], "cvssMetricV31": [{"type": "Secondary", "source": "ics-cert@hq.dhs.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 4.8, "attackVector": "ADJACENT_NETWORK", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "HIGH", "availabilityImpact": "NONE", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "impactScore": 3.6, "exploitabilityScore": 1.2}]}, "published": "2018-05-04T18:29:00.570", "references": [{"url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/carelink-2090-29901.html", "source": "ics-cert@hq.dhs.gov"}, {"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-18-058-01", "source": "ics-cert@hq.dhs.gov"}, {"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-058-01", "tags": ["Third Party Advisory", "US Government Resource"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "ics-cert@hq.dhs.gov", "description": [{"lang": "en", "value": "CWE-23"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-22"}]}], "descriptions": [{"lang": "en", "value": "Medtronic 2090 CareLink Programmer\u2019s software deployment network contains a directory traversal vulnerability that could allow an attacker to read files on the system."}, {"lang": "es", "value": "Todas las versiones de Medtronic 2090 Carelink Programmer se han visto afectadas por una vulnerabilidad de salto de directorio en la que la red de despliegue del software del producto podr\u00eda permitir que un atacante lea archivos en el sistema."}], "lastModified": "2025-05-22T18:15:23.033", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:medtronic:2090_carelink_programmer_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "884B08DC-B6F9-4B34-9679-61C256437DF9"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:medtronic:2090_carelink_programmer:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "215ED381-B433-4D05-97AD-4E7287E5820D"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "ics-cert@hq.dhs.gov"}