Show plain JSON{"id": "CVE-2016-9154", "cveTags": [], "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 5.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "PARTIAL"}, "acInsufInfo": true, "impactScore": 2.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV30": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 3.6, "exploitabilityScore": 3.9}]}, "published": "2016-12-23T05:59:00.593", "references": [{"url": "http://www.securityfocus.com/bid/94962", "tags": ["Third Party Advisory", "VDB Entry"], "source": "productcert@siemens.com"}, {"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-856492.pdf", "tags": ["Mitigation", "Vendor Advisory"], "source": "productcert@siemens.com"}, {"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-355-01", "tags": ["Third Party Advisory", "US Government Resource"], "source": "productcert@siemens.com"}, {"url": "http://www.securityfocus.com/bid/94962", "tags": ["Third Party Advisory", "VDB Entry"], "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-856492.pdf", "tags": ["Mitigation", "Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}, {"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-355-01", "tags": ["Third Party Advisory", "US Government Resource"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Deferred", "weaknesses": [{"type": "Secondary", "source": "productcert@siemens.com", "description": [{"lang": "en", "value": "CWE-332"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-332"}]}], "descriptions": [{"lang": "en", "value": "Siemens Desigo PX Web modules PXA40-W0, PXA40-W1, PXA40-W2 for Desigo PX automation controllers PXC00-E.D, PXC50-E.D, PXC100-E.D, PXC200-E.D (All firmware versions < V6.00.046) and Desigo PX Web modules PXA30-W0, PXA30-W1, PXA30-W2 for Desigo PX automation controllers PXC00-U, PXC64-U, PXC128-U (All firmware versions < V6.00.046) use a pseudo random number generator with insufficient entropy to generate certificates for HTTPS, potentially allowing remote attackers to reconstruct the corresponding private key."}, {"lang": "es", "value": "Los m\u00f3dulos Siemens Desigo PX Web PXA40-W0, PXA40-W1, PXA40-W2 para controladores autom\u00e1ticos Desigo PX PXC00-E.D, PXC50-E.D, PXC100-E.D, PXC200-E.D (todas las versiones de firmware < V6.00.046) y m\u00f3dulos web Desigo PX PXA30-W0, PXA30-W1, PXA30-W2 para controladores autom\u00e1ticos Desigo PX PXC00-U, PXC64-U, PXC128-U (todas las versiones de firmware < V6.00.046) utilizan un generador de n\u00fameros pseudoaleatorios con entrop\u00eda insuficiente para generar certificados HTTPS, potencialmente permite a atacantes remotos recontruir la clave privada correspondiente."}], "lastModified": "2025-04-12T10:46:40.837", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:siemens:desigo_web_module_pxa30-w0_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C5C10637-A57E-4962-AB67-AE4011D2C089", "versionEndIncluding": "6.00.00"}, {"criteria": "cpe:2.3:a:siemens:desigo_web_module_pxa30-w1_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "6286131E-6399-48E4-919F-0190747B8E44", "versionEndIncluding": "6.00.00"}, {"criteria": "cpe:2.3:a:siemens:desigo_web_module_pxa30-w2_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "88E1B0C0-26EF-4D5E-AF6B-D6E0FA262DAE", "versionEndIncluding": "6.00.00"}, {"criteria": "cpe:2.3:a:siemens:desigo_web_module_pxa40-w0_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "DE4D4A9B-806A-4B40-83A7-C94757D17438", "versionEndIncluding": "6.00.00"}, {"criteria": "cpe:2.3:a:siemens:desigo_web_module_pxa40-w1_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "F7DA287F-D035-4938-82F6-0115D6A486DC", "versionEndIncluding": "6.00.00"}, {"criteria": "cpe:2.3:a:siemens:desigo_web_module_pxa40-w2_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "5BFB5ABF-932D-4912-9B40-0DF467DE1BEF", "versionEndIncluding": "6.00.00"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:desigo_web_module_pxa30-w0:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "56BC0886-95F1-4FF1-9F91-2CBDDD1AA591"}, {"criteria": "cpe:2.3:h:siemens:desigo_web_module_pxa30-w1:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "6D92AC0D-D075-49B4-B93B-B9F916FF09B3"}, {"criteria": "cpe:2.3:h:siemens:desigo_web_module_pxa30-w2:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "5F827A9C-8BF8-43FE-818E-DBA46FCD6767"}, {"criteria": "cpe:2.3:h:siemens:desigo_web_module_pxa40-w0:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "5BE371AF-ECE2-4C1C-8F02-F4D984D4FFEF"}, {"criteria": "cpe:2.3:h:siemens:desigo_web_module_pxa40-w1:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "DD216D86-3876-4086-B44D-EDF1838AE286"}, {"criteria": "cpe:2.3:h:siemens:desigo_web_module_pxa40-w2:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "AFA222E8-9A0B-4F2B-9EEB-4ED666079321"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "productcert@siemens.com"}